2.645-193.0/
Universal hose coupling Plus, for 1/
2.645-203.0
2", 5/8" and 3/4" hoses
2.645-148.0
Hose PrimoFlex plus, 25 m, 3/4"
Caution
To avoid risks, all repairs and replacement of spare parts may only be carried out by authorized customer service
personnel.
First pull out the plug from the mains before carrying out any tasks on the machine.
Fault
Pump runs but does not
transport
Pump does not run or
suddenly comes to a
standstill during opera-
tions
Pumping capacity is re-
ducing
Pumping capacity too
low
Our Kärcher branch will be pleased to help you further in the case of questions or faults. See address on the reverse.

Special accessories

Troubleshooting
Cause
Air in the pump
Suction area blocked
(only in manual mode) Water level be-
low the minimum water level
Pressure hose is blocked
Locking tap is closed (arrow horizontal). Open the locking tap (arrow vertical).
Power supply interrupted
Thermal protection switch in the motor
has switched off the pump as it was
overheated.
Dirt particles have got jammed into the
suction area
Pump operation stopped by sensor
Suction area blocked
The pumping capacity depends on the
flow height, hose diameter and hose
length.
Recessed grips made of soft plastic ensure easy han-
dling. Universally useable for all common garden hoses.
Phthalate-free 3/4" garden hose for connecting the
pump with the application equipment.
Remedy
Plug in/ pull out the mains plug of the pump a few
times till the fluid gets sucked
Pull out the mains plug and clean the suction area
Immerse the pump deeper into the liquid, if possible.
Pull out the mains plug and clean the pressure
hose
Check fuses and electrical connections
Pull out the mains plug, let the pump cool down,
clean the suction area, prevent dry running
Pull out the mains plug and clean the suction area
Check position of level sensor
Pull out the mains plug and clean the suction area
Keep max. flow height, see technical data. If neces-
sary, select a different hose diameter or hose
length.