EQUATION EQI-80R Instrucciones Para Instalación, Uso Y Mantenimiento página 22

Insertable
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
5. LIGHTING AND REGULATING COMBUSTION
The Insert must be closed at all times during
combustion to prevent smoke from leaking
out. Only open to reload.
Follow
the
instructions
combustion:
- TURN the handle on the ash pan cover from 0º
to 90º for a greater provision of air to improve the
combustion process. The door opens slightly.
To favour the lighting up process, we recommend
adjusting the ash pan cover to 90ª to allow a
greater provision of air to improve the combustion
process.
It is essential to provide an abundant load of fuel
when lighting. The following loads will depend on
the heat requirement desired.
It is advisable to leave the door partially open to
avoid condensation and keep the glass clean for
some minutes after lighting the fire.
Once the fireplace has got going at its normal
level and the chimney has heated up, regulate
combustion by means of the regulation lever.
When the inflow of air is fully closed, combustion
will be slow; when the inflow of air is open,
combustion will be more intense.
In order to make the most of your device,
place the combustion regulation lever in the
central position.
When the device is to be used in the same room
as other heating devices that require air for
combustion
purposes,
additional inflow of air from outside to facilitate
combustion in all the said devices.
The use of one or more heating devices in the
same room reduces the level of available oxygen,
affecting the combustion of the fireplace and
reducing the draw of the chimney.
The top part of the front glass pane does not
include any sealing in order to allow air to enter to
Clean the glass during combustion; this inflow of
air is constant and cannot be regulated,
below
to
regulate
we
recommend
an
Totalmente
Fully open
abiertoº
Parcialmente Abiertoº
Part Open
The said inflow of air also allows a secondary
combustion process at the top part of the device.
By adjusting the handle on the ash pan
cover, a greater provision of air can be obtained to
improve the combustion process. This provision of
air enters through the lower section of the log tray
and reaches the centre of the cast iron bottom
section. (Each time you load fuel, check that these
air intakes are free from the accumulation of ash,
otherwise, they should be cleaned to facilitate
correct combustion)
ATTENTION! When working, the metal parts
of the fireplace may reach high temperatures.
Protect your hands with a fireproof glove
when touching the said parts.
If you should detect any overheating of the
fireplace caused by:
Fan breakdown.
Faulty thermostat.
You should shut down the device in order to avoid
damaging
cast
recommendations:
• Do not add any more fuel
• Open the door slightly to let more air in; this
will cause the flames to grow and consume the
fuel more quickly but will also cool the chimney
and reduce draw, cooling the device
Your Insert has not been designed to operate
with an intermittent combustion system
180º
Cerradoº
Closed
90º
iron
parts.
Follow
these

Publicidad

Tabla de contenido
loading

Tabla de contenido