(1) Connector pin configuration
No.
Signa l
1
FG
2
DRAWER1
3
DRSW
4
VDR
5
DRAWER2
6
GND
(2) Electric characteristics
1)
Drive voltage: 24 VDC
2)
Drive current: Approx. 1 A max. (not to exceed 510 ms.)
3)
DRSW signal: Signal levels: "L" = 0 to 0.8 V, "H" = 2 to 3.3 V
(3) DRSW signal
DRSW signal status can be tested with the DLE+EOT, GS+a, or GS+r
command or at pin 34 on the parallel interface port.
(4) Drive circuit
CAUTION
Cash drawers 1 and 2 cannot be operated at the same time.
The solenoid used for the cash drawer should be 24 or more. Do not allow the
electric current to exceed 1 A. Excessive current could damage or burn out the
circuits.
Calle Llanos de Jerez 18 Nave 9 Coslada https://v10consumibles.com Tel: 910 269 309
Function
Frame ground
Cash drawer 1 drive signal
Cash drawer switch input
Cash drawer drive power supply
Cash drawer 2 drive signal
Signal ground (common ground on
circuits)
Cash drawer kick-out connector
Shielded
Cash drawer open/
close switch
Cash drawer
V10 CONSUMIBLES S.L.
Printer
— 32 —
Connector used:
TM5RJ3-66 (Hirose) or
equivalent
Applicable connector:
TM3P-66P (Hirose) or
equivalent