PRESIDENT AA50075 Manual Del Operador página 26

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

G G
B B
A - ELECTRIC CONNECTION
- B -
SW1 - MICROSWITHCES FOR THE GEARCASE
SETTING
DIP 1 - MOTOR
DECELERATION
(POINT C)
DIP 2 - PROGRAMMING TIMES (ON)
OPERATING MICROSWITCH
DIP 3 - Waiting time before the automatic closing (ON) (max 5
min.)
DIP 4 - Step by step radio receiver (OFF) - automatic (ON)
DIP 5 - Single impulse control (K BUTT)
step (OFF) - automatic (ON)
DIP 6 - Normal working (OFF) – Park working (ON)
DIP 7 - Encoder exclusion as security (OFF - encoder on / ON -
encoder off)
DIP 8 - Function of the key OPENING 2 check in Park mode.
ON - the key OPENING 2 is always authorized,
OFF- the key OPENING 2 is authorized only if there is no
presence on INPARK.
DIP 9 - Working after black-out WITH batteries.
ON - The rod opens and stops in the opening position with the
exclusion of all controls. When the network input is back,
the bar closes resetting all controls
OFF - The bar carries out the normal working until the battery is
exhausted.
DIP 10 - Working after black-out WITHOUT batteries.
ON - The bar closes
OFF - The bar stops in the point where the black-out happened.
S1
PROG. Key for the programming.
T
ERMINAL BOARD J1
SEC.TRANSF. Connection for secondary transformer (carried out in
the factory).
CALIBRATION
(ON)
step
by
control panel PARK 24V code BC07061
C
ONNECTOR J2
MOTOR Connection MOTOR and ENCODER (carried out in the
factory).
T
ERMINAL BOARD J3
1
Central aerial wire connection
2
Aerial cable electric shielding connection
3
Common contacts
4
Photoelectric cells contact (NC)
5
Stop button contact (NC)
6
Opening 1 button contact (NA)
7
Closing button contact (NA)
8
Single impulse contact (NA)
9
Positive for fixtures input (+24Vdc)
10 Negative for fixtures input (-24Vdc)
11
Battery state connection led (12Vdc)
12 Sounding signaller connection (12Vdc max 200mA)
13 Negative for flashlight input 24Vdc (9+ / 13-)
T
ERMINAL BOARD J4
SECURITY LOCK Connector for manual release security (connected
in the factory - DO NOT REMOVE !)
T
ERMINAL BOARD J5
SW Connector dedicated to the programming in the factory.
DO NOT TOUCH THE JUMPER WHICH IS IN THE
POSITION INDICATED IN THE FIGURE!
T
ERMINAL BOARD J6
EXP. 12VEXPANDER board connector (vrs. 12/24V code ACG5471).
C
ONNECTOR J7
RADIO Radio receiver with a 24Vdc input connector.
C
ONNECTOR J8
BATTERY CHARGER Battery charger board connector (code ACG4661).