ACCESSORIES -
A
DDITIONAL FUNCTIONS WITH
)
BOARD (code ACG5471
EXPANDER 24V
!! ENGAGE THE
CURRENT !!
L
EGENDA
TR => courtesy light time regulation trimmer
1-2 => 24Vdc feeding for photoelectric cells, fotostrips, etc.....
3-4 => Traffic signal contact EXIT 1
5-6 => Traffic signal contact EXIT 2
7-8 => Courtesy light contact
9
=> OPENING 2 Contact (NO)
10
=> IN PARK Contact (NO)
11
=> Control OK CLOSE (NO)
12
=> Common
EXPANDER 24V
BOARD LED SIGNALING
D2 OPENING 2 control contact signalling
D3 IN PARK contact signalling
D4 OK CLOSE contact signalling
D5 Presence of tension
N.B.: For a correct functioning the LED D5 must always be on.
ATTENTION: THE PARK BOARD, THROUGH THE DIP 6 ENABLES
OR NOT SOME CONTROLS OF THE EXPANDER
BOARD, THUS KEEP ATTENTION:
IF DIP 6 OFF NORMAL FUNCTIONING,
THE OPENING CONTROLS 2, OK CLOSE AND IN PARK ARE NOT
ACTIVE, WHILE THE MANAGEMENT TRAFFIC SIGNAL AND THE
COURTESY LIGHT ARE AVAILABLE.
MANAGEMENT TRAFFIC SIGNAL WITH NORMAL FUNCTIONING
WITH EXPANDER
- DRAWING B -
PRESIDENT CLOSE
PRESIDENT OPENS WITH OPENING 1
PRESIDENT OPEN
PRESIDENT IN CLOSING
For the connections and the technical data of the optional equipments follow the relevant
handbooks.
EXPANDER 24V
BOARD IN ABSENCE OF
D5
D4
D3
D2
EXIT 1 (NO)
EXIT 2 (NO)
RED IN
GREEN IN
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
- DRAWING D -
EXIT 1(NC) EXIT 1(NO) EXIT 2(NC) EXIT 2 (NO)
RED IN
PRESIDENT CLOSE
ON
PRES. OPENS W/OPENING 1 ON
PRESIDENT OPEN
OFF
PRESIDENT IN CLOSING
ON
PRESIDENT CLOSE
ON
PRES. OPENS WI/OPENING 2ON
PRESIDENT OPEN
ON
PRESIDENT IN CLOSING
ON
PARK DIP 6 FUNCTIONING MODE ON WITH EXPANDER CARD
(SEE DRAWING D)
TO ENTER:
On condition that a vehicle is present on the magnetic sensor, the
opening of the bar can be operated through the opening 1 BUTTON,
step by step or radio control. The bar will be open until the vehicle has
passed by the photoelectric cells placed in correspondence to the
passage completion line. The closing is carried out a second after the
said passage (released photoelectric cell), and is protected by
photoelectric cells. These will operate the inversion of the opening bar
even if the vehicle stays within the range of the securities.
TO EXIT:
The opening of the bar is enabled through the button OPENING 2
connected to a magnetic sensor or to other devices, on condition that
no vehicle is present on the entry magnetic sensor (see DIP 8 for the
exclusion of the input blocks). The bar will be open until the vehicle has
passed by the photoelectric cells placed in correspondence to the
passage completion line. The closing is carried out a second after the
said passage (released photoelectric cell), and is protected by
photoelectric cells. These will operate the inversion of the opening bar
even if the vehicle stays within the range of the securities.
ATTENTION: The waiting time before the automatic closing will be
counted only if "DIP 3 ON".
As a consequence, if "DIP 3 OFF" and if the vehicle stays too long on
the magnetic sensor without transiting (without taking up the
photoelectric cell ), the bar will close after the set up time.
O
PENING BUTTON 2 (9-12)
Control dedicated to the opening of the bar to exit from the parking
place with management of the traffic signal right of way signalling.
This control is cut out if the IN PARK control is activated (presence of
vehicle in entry).
O
K CLOSE CONTROL (11-12)
It enables the closing of the bar 1 second after the vehicle has passed.
Normally this control is operated by a photoelectric cell or by a magnetic
sensor placed on the bar's closing line.
If the control is inserted, the bar doesn't close back.
I
N PARK CONTROL (10-12)
The "IN-PARK" entry (NA) must be connected to a magnetic sensor
placed next to the bar and it signals the presence of an incoming
vehicle (if you don't want to make use of this function make a bond
between terminal 10 and 12).
Only the presence of a vehicle enables the opening of the bar in
working mode PARK through the control opening 1.
C
OURTESY LIGHT (7-8)
It is possible to feed the coil of a relay (24VDC) so to activate one or
more lights for a min. time of 1 sec. And a max. time of 4 seconds
(adjustable through the trimmer TR on the side of the EXPANDER 24V
GREEN IN RED OUT GREENOUT
OFF
ON
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
OFF
G G
B B

Publicidad