B B
about 20V, after which we have a signalling given by the
recharge card of the gearcase which blocks the bar and
makes the battery state pilot light lighten. Once the
network voltage is back, the recharge card starts
charging the battery and the battery state led switches
off. It is sufficient to press the remote control (or the
opening button 1 or 2 or the step by step button ) to
open the bar. When the bar is open, give a closing
command or wait the pause time before the automatic
closing => the bar starts closing. When closed, the
normal functions are reactivated.
DIP 9 - ON => with lack of network voltage the bar opens automatically,
the battery state led switches on and all controls are
inhibited. When the network voltage is back, the bar
closes immediately thus resetting the controls and
safeties functioning.
IN CASE NO BATTERY IS CONNECTED, through the DIP 10 you can
have the following options:
DIP 10 - OFF =>In lack of the network voltage the bar stays still or, in
case it is moving, it stops. Once the network voltage is
back, it is sufficient to press the remote control, 1 and 2
OPENING buttons or step by step button to open the
bar. When the bar is open, give a closing command or
wait the pause time before the automatic closing => The
bar starts closing => When closed, the normal functions
are reactivated. During the realignment the securities
are active.
DIP 10 - ON => At the return of the network voltage the bar closes if
open, and doesn't close only in case the clock function
is active. (see OPENING 1 button).
S
AFETY FITTINGS OPERATION
S
ECURITY LOCK
For a correct functioning of the system, the DL4 led must always be on
to signal that the manual release has not been activated. If the DL4 led
is off no movement of the bar is allowed because it has been manually
released with the special key.
E
NCODER
It has the duty to act as security and to define the running, both during
the closing and the opening phase, with reversal of the movement.
It is possible to exclude the ENCODER, which only functions as
security, through DIP 7 (OFF).
In case the ENCODER should not work (not fed, disconnected wires or
faulty) the movement of the bar is not carried out.
If after a first intervention of the ENCODER in closing or opening phase
there is a second one, obviously in the contrary sense, the bar stops
and then reverses for 1 sec. The bell (buzzer optional) will be activated
to signal the alarm state for 5 minutes and the flashlight will be active
for a minute.
During or after the 5 minutes of sounding alarm (buzzer optional), it is
possible to reset the functioning of the bar by pressing any control
button.
P
HOTOELECTRIC CELL (terminals 3-4)
When the bar is down, if there is an obstacle in the radium of the
photoelectric cells and the opening command is given, the bar opens
(during the opening phase the photoelectric cells will not work).
The photoelectric cells will only work during the closing phase (with
reset of the reverse motion after a second even if they are busy).
N.B.: Every six months make sure to check that photocells are not
out of order.
S
TOP BUTTON (terminals 3-5)
During whatever operation the STOP button stops the bar.
If pressed when the bar is completely open the automatic closing is
temporarily excluded (if selected through DIP3). It is thus necessary to
give a new command to make it close again.
At the following cycle the automatic closing function is reactivated (if
selected through DIP3).
F
LASHLIGHT (terminals 9 positive / 13 negative)
N.B.: This electronic board can feed ONLY FLASHLIGHTS WITH
LIGHTENING CIRCUIT and a 24V lamp.
The flashlight is active during the motion of the bar, or to signal the
impact alarm state for 1 minute.
Use a flashlight (code ACG7061) with a max. 24V 20W lamp.
B
UZZER (Optional - terminals 3 positive / 12 negative)
During the opening and the closing phase the buzzer will give a
sounding intermittent signal.
In case of intervention of the securities (alarm) this sounding signal
increases the frequency of the intermittence.
Power provided for the functioning of the 200mA buzzer at 12Vdc.
T
ECHNICAL CHARACTERISTICS
- Humidity
- Feeding tension
- Frequency
- Battery feeding
- Transformer power
- Standby modus
- Network micro interruptions
- Flashlight max. load
- Power available for per photoelectric cells and fixtures
- Power available on radio connector
- All the inputs must be used as clear contacts because the power
supply is generated inside (safe power) the control panel, and it has
been laid down in such a way to guarantee a double or strengthened
insulation in relation to the parts with dangerous power.
- Eventual external circuits connected to the outputs of the control
board or of the expander card must be carried out making sure that a
double or strengthened insulation is used in relation to parts with
dangerous power.
- All inputs are run by a programmed integrated circuit which does a self
check every time it starts operating.
< 95% without condensation
230V~ ±10%
50/60 Hz
20-24,5Vdc
130VA - V primary 230 Vac - V
Secondary 18Vac
100mA
100ms
24Vdc 20W
1A ±15%
200mA