C
ONNECTOR J9
L1 - N Input 230 Vac 50/60 Hz (external to the board).
L
ED SIGNALINGS
DL1 - (Red)
- Encoder working check
DL2 - (Red)
- Stop contact (NC)
DL3 - (Red)
- Photoelectric cells contact (NC)
DL4 - (Red)
- Manual release security (NC)
DL5 - (Red)
- Active programming
DL6 - (Green) - Opening rod
DL7 - (Red)
- Closing rod
- C -
MOTOR DECELERATION CALIBRATION
This control is meant to facilitate the installer during the installation of
the system, or during possible further checks.
1 - Set DIP1 on ON => The led DL5 starts to lighten.
2 - Press and keep pressed the button PROG. (now the movement is
carried out with a man present, open-stop-close-stop-open-etc.) =>
THE RED LED DL7 switches on and the bar closes.
3 - Press and keep pressed the button PROG => THE GREEN LED
DL6 switches on and the bar opens.
4 - Carry out the calibration of the deceleration speed
trimmer LOW SPEED at the minimum, than press the small button
and keep it pressed => after one second working the deceleration
is activated.
ATTENTION: Verify that the motor has enough power to move the rod
both when opening and closing. Contrariwise, increase
the value set on the trimmer until the optimal condition for
working is reached.
ATTENTION: In areas subject to particularly rigid temperatures, rotate
the trimmer 5° clockwise more than the normal value.
5 - At the end of the check set DIP1 back on OFF => TheDL5 led
switches off thus signalling the exit from the check.
N.B.: During this check the ENCODER and the photoelectric cells are
active.
- D -
TIMES PROGRAMMING
THIS PROCEDURE IS NORMALLY CARRIED OUT IN THE
FACTORY, BUT IT MUST BE REPEATED IN CASE YOU WISH TO
SET AN AUTOMATIC CLOSING TIME.
1 - When the bar is entirely closed (very important for a correct learning
of the stroke).
2 - Set the micro switcher DIP 2 on ON => The DL5 led will emit short
flashings.
3 - Press the button PROG. => the bar opens.
4 - Once the mechanic opening clamp is reached, the ENCODER stops
the motor (with encoder and time readings) and the waiting time
calculation before the automatic closing becomes active (max 5
minutes).
5 - Press the button PROG. => The waiting time calculation before the
automatic closing stops and the bar closes. In the same moment,
the DL5 led stops lightening thus signalling the exit from the
machine learning procedure.
From this moment the securities or other controls of the gate will
normally work (reversals, stop, alarms, etc....).
6 - The closing of the bar will be carried out in speed mode and in the
proximity of the total closing in slow down mode.
7 - Once the ENCODER calculation is over, the bar stops.
AT THE END OF THE PROGRAMMING PUT THE DIP 2 BACK ON
OFF.
DURING THE PROGRAMMING THE SECURITIES ARE ACTIVE AND
THEIR INTERVENTION STOPS THE PROGRAMMING (THE LED
DL5 WHICH WAS LIGHTENING NOW HAS A COSTANT LIGHT ). TO
REPEAT THE PROGRAMMING SET THE DIP 2 ON OFF), CLOSE
THE
BAR
DECELERATION
PROGRAMMING DESCRIBED ABOVE.
C
ONTROL FITTINGS OPERATION
O
PENING BUTTON 1 (terminals 3-6) with clock function
When the bar is stationary the button operates the opening movement.
If it is operated during the closing phase it makes the bar open again.
In Park working mode(dip 6 on) the opening of the bar to enter the
parking place is allowed.
C
LOCK FUNCTION
This function is useful during the peak hours, when the vehicles traffic
slows down (e.g. entry/exit workers, emergencies in residential areas or
parking places and, temporarily, for moves).
APPLICATION MODES
By connecting a switch and/or a clock of daily/weekly kind (instead of or
in parallel with an opening N.A. button "terminals 3-6), it is possible to
open and to keep open the automation until the switch is pressed or the
clock is active.
When the automation is open, all control functions are inhibited.
=> set the
If the automatic closing is active, by releasing the switch, or anyway
when the set hour expires, there will be the immediate closing of the
automation, contrariwise it will be necessary to give a command.
C
LOSING BUTTON (terminals 3-7)
When the bar is open operate the closing movement.
C
ONTROL STEP BY STEP BUTTON (terminals 3-8)
DIP5 - OFF => Carries out a cyclic control of open-stop-close-stop-
DIP5 - ON => Carries out the opening when the bar is closed. If it is
R
EMOTE CONTROL
DIP4 - OFF => Carries out a cyclic control of open-stop-close-stop-
DIP4 - ON => Carries out the opening when the bar is close. If it is
A
UTOMATIC CLOSING
The pause times before the automatic closing of the bar are recorded
during the times programming.
The max. pause time is 5 minutes.
The pause time can be activated or deactivated through DIP3 (ON -
active).
R
ELEASE FACILITATION
When the closing will be completed a reversal manoeuvre will be
carried out for a fixed time of 0,06s to facilitate the manual release.(in
this phase the ENCODER is not enabled).
F
UNCTIONING WITH BLACK OUT
IF TWO 12V BATTERIES ARE CONNECTED in series to the recharge
card positioned in the gearcase, through the dip 9 we can have the
following options:
DIP 9 - OFF => with lack of network voltage the bar opens and closes
FOLLOWING
THE
PROCEDURE
CALIBRATION"
AND
open-etc. controls.
operated during the opening movement it has no effect.
If it is operated when the bar is open, it closes it. If it is
operated during the closing movement it makes it open
again.
open-etc. controls.
operated during the opening movement it has no effect.
If it is operated when the bar is open, it closes it. If it is
operated during the closing movement it makes it open
again.
normally, the battery state pilot light switches on thus
signalling the functioning with the battery. The
functioning of the bar is ensured up to a voltage level of
G G
B B
"MOTOR
REPEAT
THE