Ghibli - GB Seite 10 Freitag, 11. Mai 2007 11:03 11

Putting into Operation

Check the mains connection and the plug for mechanical defects!
Observe mains voltage: The mains voltage must agree with the data on the type plate of the unit. Extension cords
must have a cross section of at least 2 x 1.5 mm
Switching On:
Adjust the air volume as required with the two-position switch 3 and/or the air slide 11. Adjust the temperature as
required with potentiometer 2. Set the power switch 1 to I. The heat-up period is approx. 5 minutes.
Switching Off:
Turn the potentiometer 2 to the 0 position in order for the unit to cool down. When the unit has cooled down, set
the switch 1 to 0.
Operating Instructions
– Practical demonstrations of the applications are available free-of-charge at Leister Technologies as well as
through our after-sales service agents.
– Perform a test welding according to the welding instructions of the material manufacturer and the national stand-
ards or guidelines. Check the test welding. Adapt the welding temperature as required.

Maintenance, Service and Repairs

– Check mains connection and plug for interruption and mechanical damage.
– Before any work on the unit: Pull the mains plug.
– For secure and proper operation, keep the unit and the ventilation slots clean at all times.
– Use only original Leister accessories.
– When contaminated, clean the air filter 9 of the switched off unit using a brush. Replace a damaged or heavily
contaminated air filter.
– The operating lifetime of the carbon brushes is approx. 1200 hours. Have carbon brushes replaced through an
authorized Leister after-sales service.
If the unit should fail despite the care taken in manufacturing and testing procedures, repair should be carried out
by an authorized Leister after-sales service agent.
Warranty
For this tool, the guarantee or warranty rights granted by the relevant distributor/seller shall apply. In case of
guarantee or warranty claims any manufacturing or workmanship defects will either be repaired or replaced
by the distributor at its discretion. Warranty or guarantee rights have to be verified by an invoice or a delivery
document. Heating elements shall be excluded from warranty or guarantee.
Additional guarantee or warranty claims shall be excluded, subject to mandatory provisions of law.
Warranty or guarantee shall not apply to defects caused by normal wear and tear, overload or improper
handling.
Warranty or guarantee claims will be rejected for tools that have been altered or changed by the purchaser.
Translation of the Original User Manual
English - 10 -