Accessories; Trouble Shooting - Emerson PRO Serie II Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Ceiling Fan/Light Controls (see store or catalog).
Downrod Extension Kits (see store or catalog).
!
The use of any other control not specifically approved
for this fan could result in fire, shock and personal
injury.
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
!
TROUBLE SHOOTING YOUR FAN.
TROUBLE
1.Fan will not start. 1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan,
or loose switch wire connections in the
switch housing.
3. Reversing switch in neutral position.
2.Fan sounds noisy. 1. Blades not attached to fan.
2. Screws securing fan blade flanges to
motor hub are loose.
3. Wire connectors inside switch housing
rattling.
4. Motor noise caused by solid-state variable
speed control.
3.Fan wobbles
5. Screws holding blades to flanges are loose.
excessively.
1. Setscrews in motor coupling are loose.
2. Setscrew in hanger ball/downrod assembly
is loose.
3. Screws securing fan blade flanges to
motor are loose.
4. Fan blade flanges not seated properly.
5. Hanger bracket and/or ceiling outlet box
is not securely fastened.
6. Fan blades out of balance.

16. Accessories

WARNING

17. Trouble Shooting

PROBABLE CAUSE
PROBABLE
!
This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Co. could result in personal injury
or property damage.
SUGGESTED REMEDY
1. Check main and branch circuit fuses or circuit breakers.
2. Check line wire connections to fan and switch wire
connections in the switch housing.
WARNING: Make sure main power is turned off.
!
3. Make sure reversing switch position is all the way to one
side.
1. Attach blades to fan before operating.
2. Check to make sure the screws which attach the fan
flanges to the motor hub are tight.
3. Check to make sure wire connectors in switch housing
are not rattling against each other or against the interior
WARNING: Make sure main power is turned off.
wall of the switch housing.
!
4. Some fan motors are sensitive to signals from Solid-
State variable speed controls. If Solid-State Control
is used and motor noise results choose an alternative
control method.
5. Tighten screws securely.
1. Tighten both setscrews securely in the motor coupling.
2. Tighten the setscrew in the hanger ball/downrod
assembly.
3. Check to be sure screws which attach the fan blade
flanges to the motor are tight.
4. Check to be sure the fan blade flanges seat firmly and
uniformly to the surface of the motor.
5. Tighten the hanger bracket screws to the outlet box,
and/or secure outlet box.
6. Interchanging an adjacent (side-by-side) blade pair can
redistribute the weight and result in smoother operation.
22
WARNING
U.L. Model No.: 42-ANT & 52-ANT

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido