Installation
Commissioning
10.3.11 Installation for offset tiles
This appliance can be installed where tiles are offset. See diagram
for maximum tile offset and minimum contact area of the appli-
ance. Adjust the wall clearance and lock the back panel with the
fixing toggle by turning it clockwise through 90°.
Installation dimensions for offset tiles
20
www.stiebel-eltron.com
11. Commissioning
11.1 Initial start-up
Danger to life through electrocution!
Commissioning must only be carried out by an author-
ised contractor in accordance with safety regulations.
Commissioning
f Open and close all connected draw-off valves several times.
f
Continue until the line network and the appliance are free
of air.
f Activate the safety pressure limiter. The instantaneous water
f
heater is delivered with the safety pressure limiter triggered.
Activate the safety pressure switch at flow pressure by press-
ing the reset button.
f Push the temperature selector plug into the "set tempera-
f
ture" PCB.
f Fit the appliance cap and secure with a screw.
f
f Switch the mains power ON.
f
f Calibrate the temperature. For this, turn the temperature se-
f
lector fully clockwise then fully anti-clockwise.
f Check the appliance function.
f
f Remove the protective foil from the user interface.
f