Descargar Imprimir esta página

Balluff BML-S2C0-Q Serie Manual Del Usuario página 6

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
BML-S2C0-Q _ _ _ -M6 _ _ - _ 0-KA _ _ /KF _ _ /KA _ _-S284
Incremental Magnetic Linear Encoder
Installation and connection (continued)
NOTICE!
Interference in function
Improper assembly of the magnetic tape and sensor
head may impair function of the position measuring
system and lead to increased wear or damage to the
system.
► All permissible distance and angle tolerances must
be strictly complied with.
► The sensor head may not come into contact with
the magnetic tape over the entire measuring range.
Contact must also be avoided if the magnetic tape is
covered by a cover strip (optional).
► The position measuring system must be installed in
accordance with the indicated degree of protection.
External magnetic fields change the functional properties.
► The magnetic tape may not be influenced by strong
external magnetic fields (> 30 mT).
► Direct contact with magnetic clamps or other
permanent magnets must be avoided.
No forces may be exerted on the cable on the housing.
► Provide the cable with a strain relief.
A too-high tightening torque may damage the housing.
► Tighten the mounting screws (M3x14-8.8 cylinder
screws according to DIN 912) with a torque of
< 0.7 Nm.
BML-S2C0-Q53_... (HTL output)
-S284
-KA
Wire color
Pin
1
WH
White
2
BN
Braun
3
GN
Green
4
YE
Yellow
5
GY
Gray
6
PK
Pink
7
BU
Blue
8
RD
Red
9
BK
Black
10
VT
violet
11
GY-PK
Gray/pink
12
RD-BU
Red/blue
Trans-
Shield
TR
parent
2
english
-KF
-M624- -M604- -M620- -M600-
Wire color
WH
White
BN
Braun
Not used
GN
Green
YE
Yellow
Not used
Not
GY
Gray
+Z
used
PK
Pink
Not used
BU
Blue
GND
RD
Red
GND sense
UB sense
+Nerror
Not used
Trans-
TR
parent
BML-S2C0-...-KA_ _-S284
2
11 3
10
4
1
5
9
12
6
8
7
M12 plug pin assignment (view on pin side)
+A
Rectangular signal
+B
Rectangular signal, 90° phase-delayed to A
Not
+Z
Reference signal
used
Sensor head ground (0 V)
UB
Supply voltage 10 to 30 V DC
GND sense
UB sense
Not used
Error signal
PE
PH shield PE connector housing/shield
Description

Publicidad