Your Peace of Mind is Our Top Priority
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
Register your
Zoeller Pump Company
Product on our website:
http://reg.zoellerpumps.com/
AVAILABLE MODELS HIGH TEMPERATURE PUMPS
SERIES
3098
3137
3139
3161
3163
3282
Nonautomatic (N or E) models with a watertight junction box (for outdoor or above ground installations) are available in all series.
PREINSTALLATION CHECKLIST - ALL INSTALLATIONS
1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. DO NOT remove the test plugs in the cover
nor the motor housing.
2. Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future reference.
1. Make sure there is a properly grounded receptacle available. All pumps are
furnished with provisions for proper grounding to protect you against the possibility
of electrical shock.
(SEE WARNING BELOW)
2. Make certain that the receptacle is within the reach of the pump's power supply cord.
DO NOT USE AN EXTENSION CORD. Extension cords that are too long or too light
do not deliver sufficient voltage to the pump motor, and they could present a safety
hazard if the insulation were to become damaged or the connection end were to fall
into a damp or wet area.
3. Make sure the pump electrical supply circuit is equipped with fuses or circuit
breakers of proper capacity. A separate branch circuit is recommended, sized ac-
cording to the "National Electrical Code" for the current shown on the pump nameplate.
4. Testing for ground. As a safety measure, each electrical outlet should be checked
for ground using an Underwriters Laboratory Listed circuit analyzer which will indicate
if the power, neutral and ground wires are correctly connected to your outlet. If they
are not, call a qualified, licensed electrician.
5. For Added Safety. Pumping and other equipment with a 3-prong grounded plug must
be connected to a 3-prong grounded receptacle. For added safety, the receptacle
may be protected with a ground-fault circuit interrupter. When a pump needs to be
connected in a watertight junction box, the plug can be removed and spliced to the
supply cable with proper grounding. For added safety, this circuit may be protected
by a ground-fault circuit interrupter. The complete installation must comply with the
1. Check to be certain your power source is capable of handling the voltage requirements
of the motor, as indicated on the pump name plate.
2. Check valves used in High Temperature service must be all metal swing type check
valves.
3. Repair and service should be performed by Zoeller Pump Company Authorized Service
Station only.
®
®
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 USA
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 USA
+1 (502) 778-2731 • FAX +1 (502) 774-3624
INSTALLATION INSTRUCTIONS
HP
DISCHARGE
½
1½"
½
1½"
½
1½"
½
1½" or 2" or 3"
½
1½" or 2" or 3"
½
2" or 3"
CAUTION
© Copyright 2015 Zoeller
SOLIDS
PH
½" (13 mm)
5/8" (16 mm)
5/8" (16 mm)
¾" (19 mm)
¾" (19 mm)
2" (51 mm)
SEE BELOW FOR LIST OF WARNINGS
National Electrical Code and all applicable local codes and ordinances.
6. FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER
SOURCE BEFORE HANDLING. Single phase pumps are supplied with a 3-prong
grounded plug to help protect you against the possibility of electrical shock. DO NOT,
UNDER ANY CIRCUMSTANCES, REMOVE THE GROUND PIN. The 3-prong plug
must be inserted into a mating 3-prong grounded receptacle. If the installation
does not have such a receptacle, it must be changed to the proper type, wired and
grounded in accordance with the National Electrical Code and all applicable local
codes and ordinances. Pumps must be installed in accordance with the National
Electrical Code and all applicable local codes and ordinances. Pumps are not to be
installed in locations classified as hazardous in accordance with National Electrical
Code, ANSI/NFPA 70.
7. Risk of electrical shock. Do not remove power supply cord and strain relief or con-
nect conduit directly to the pump.
8. Installation and servicing of electrical circuits and hardware should be performed by
a qualified, licensed electrician.
9. Pump installation and servicing should be performed by a qualified person.
10. Risk of electric shock. These pumps have not been investigated for use in swimming
pool and marine areas.
11. According to the state of California (Prop 65), this product contains chemicals known
to the state of California to cause cancer and birth defects or other reproductive harm.
SEE BELOW FOR LIST OF CAUTIONS
4. Dewatering and effluent sump pumps are not designed to handle raw sewage.
5. Maximum continuous operating temperature for high temperature pumps must not
exceed 200°F (93°C).
6. Cable from disconnect to control box (consumer-furnished) should be rated
194° F (90°C).
REFER TO WARRANTY ON PAGE 2.
Co. All rights reserved.
®
visit our web site:
www.zoeller.com
MATERIAL
1
Cast Iron
1
Cast Iron
1
Bronze
1
Cast Iron
1
Cast Iron
1
Cast Iron
FM0807
0315
Supersedes
1114

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Zoeller 3098 Serie

  • Página 1 6. Cable from disconnect to control box (consumer-furnished) should be rated valves. 194° F (90°C). 3. Repair and service should be performed by Zoeller Pump Company Authorized Service Station only. REFER TO WARRANTY ON PAGE 2. © Copyright 2015 Zoeller Co.
  • Página 2 DO review all applicable local and national codes and verify that the installation conforms to each of them. DO consult manufacturer for clarifications or questions. DO inspect and test system for proper operations at least every 3 months. © Copyright 2015 Zoeller Co. All rights reserved. ®...
  • Página 3 Check pump for connected to the power source. Adjust as required. proper cord/conduit length before starting assembly. Standard cord/conduit length is 3' (0.9 m). © Copyright 2015 Zoeller Co. All rights reserved. ®...
  • Página 4 If the above checklist does not uncover the problem, consult the factory. Do not attempt to service or otherwise disassemble pump. Service must be performed by Zoeller Authorized Service Stations. Go to www.zoellerpumps.com/servicestations to find the Authorized Service Station in your area.
  • Página 5: Instrucciones Para La Instalación

    105ºC (221° F). La reparación y servicio deberá hacerse solamente por personal de una estación de servicio autorizada por Zoeller Company. REFIÉRASE A LA GARANTÍA EN LA PÁGINA 6. Las bombas para achique y efluentes no están diseñadas para manejar las aguas negras.
  • Página 6: Garantía Limitada

    10. EXAMINE todos los códigos nacionales y locales aplicables y verifique que la instalación esté de acuerdo a cada uno de ellos. 11. CONSULTE con el fabricante si necesita aclaraciones o tiene preguntas. 12. INSPECCIONE y pruebe el funcionamiento del sistema por lo menos cada 3 meses. © Copyright 2015 Zoeller Co. Todos los derechos reservados. ®...
  • Página 7: Instalación Típica De Bomba Para Alta Temperatura

    El alambre y el conductor de la bomba al interruptor deben alargarse de acuerdo a ello, al momento de pedir. Revise la bomba para ver la longitud correcta del cordón/conductor antes de comenzar el montaje. La longitud corriente del cordón/conductor es de 0.9 m (3 pies). © Copyright 2015 Zoeller Co. Todos los derechos reservados. ®...
  • Página 8: Lista De Verificación Del Servicio

    Si la lista de verificación arriba mencionada no revela el problema, consulte con la fábrica. No intente hacer el servicio o de otra manera desarmar la bomba. Servicio deberá hacerse por una estación de servicio autorizada por Zoeller © Copyright 2015 Zoeller Co.
  • Página 9 3. Les réparations et l’entretien ne doivent être faits que par un centre de répara- doit être homologué pour une température d’au moins 105°C (221° F). tion agréé par Zoeller. SE RÉFÉRER À LA GARANTIE EN PAGE 10. © Copyright 2015 Zoeller Co.
  • Página 10: Garantie Limitée

    11. IL FAUT consulter le fabricant pour obtenir des clarifications ou des réponses aux questions. 12. IL FAUT inspecter le système et vérifier son fonctionnement au moins tous les trois mois. © Copyright 2015 Zoeller Co. Tous droits réservés. ®...
  • Página 11 Avant de commencer l’installation les besoins. de la pompe, vérifier la longueur du cordon et du conduit. Le cordon et le conduit ont une longueur standard de 0.9 m (3 pi). © Copyright 2015 Zoeller Co. Tous droits réservés. ®...
  • Página 12: Causes Fréquentes

    In specter la conduite. Déposer la base et inspecter. Si les vérifications ci-dessus ne résolvent le problème, consulter l’usine. Ne pas essayer de réparer ou de démonter la pompe. © Copyright 2015 Zoeller Co. Tous droits réservés. ®...