Apply
Copper Tube
plumbers putty.
2" (5.1 cm) -
2-5/8" (6.7 cm)
Setscrew
5/32" Hex
Wrench
1. Install the Spout
Slip Fit Spouts
Remove the temporary nipple from the bath elbow.
Apply thread sealant and install a 1/2" copper tube so it extends
2" (5.1 cm) to 2-5/8" (6.7 cm) beyond the finished wall.
Deburr the copper tubing.
Loosen the setscrew with a 5/32" hex wrench.
Apply a bead of plumbers putty or other sealant around the inlet
end of the spout according to the manufacturer's instructions.
Install the spout and carefully retighten the setscrew. Do not
overtighten the setscrew.
Remove all excess putty.
For Threaded Spouts
Remove the temporary nipple from the bath elbow.
Apply thread sealant, and install a 1/2" nipple so it extends
3-5/8" (9.2 cm) beyond the finished wall.
Apply a bead of plumbers putty or other sealant to the back of
the spout according to the manufacturer's instructions.
Apply thread sealant to the nipple, and install the spout to the
nipple. Carefully tighten with a clean strap wrench.
Remove excess putty.
1012741-2-F
Nipple
Slip-Fit
Spouts
3-7/8"
(9.8 cm)
4
Apply plumbers
putty.
Threaded
Spouts
Kohler Co.