Valve Stem
Retainer
Screw
Faceplate
Deep Stem Adapter
Short End
4. Install the Faceplate and Handle
Remove and discard the plaster guard and/or dome, if installed.
Position the retainer onto the valve cap and attach with the
screws provided. Securely tighten the screws.
Install the faceplate onto the retainer. The cutout on the faceplate
should face downward.
Install the pivot ring to the faceplate, and rotate clockwise to lock
in place. The pivot ring should be situated with the cutout
aligned with the faceplate cutout.
Rotate the valve stem fully counterclockwise (off position).
Determine which stem adapter should be used. Use the shallow
stem adapter if the wall depth is less than 1/4" (6 mm). Use the
short end of the deep stem adapter if the finished wall depth is
1/4" (6 mm) to 1/2" (1.3 cm) thick. Use the deep end of the deep
stem adapter if the finished wall depth is 1/2" (1.3 cm) to 3/4"
(1.9 cm) thick.
Position the stem adapter onto the valve stem with the side of the
stem adapter as horizontal and vertical as possible.
Attach the stem adapter with the supplied screws. Use the
flathead screw for the shallow stem adapter, the round head
screw for the deep stem adapter.
Align the handle to the "Off" position and hold in place while
threading the handle bonnet securely onto the retainer.
Kohler Co.
Discard plaster
guard with dome.
Cutout
Pivot Ring
Shallow Stem Adapter
Flat Head Screw
Handle Assembly
Round Head
Screw
Deep End
7
1012741-2-F