Important! Disable power before wiring up the Minibar.
Wiring:
The wiring for the permanent mount minibar is as shown in Figure
6. All wiring should be a minimum of 18AWG. The positive line must
have a 7.5 amp fuse, as shown. A switch may be used to control the
on/off function.
7.5A
920-4300-00 Rev. D
Figure 6
Sequence
Description
1
Quad (Factory Default)
2
Quad
3
Double
4
Double
5
Fast Double
6
Fast Double
7
Slow Quad
8
Slow Quad
9
Slow Double
10
Slow Double
11
Quint-hold
12
Quint-hold
13
Burst
14
Burst
15
Quad, Alternate Side-to-Side
16
Quad, Diagonal Alternate
17
Double, Alternate Side-to-Side
18
Double, Diagonal Alternate
19
Quint-hold, Alternate Side-to-Side
20
Quint-hold, Diagonal Alternate
21
Fast Rotate
22
Rotate/Quad
23
Wave Rotate
24
Random
25
Steady
Flash Mode Selection:
Flash patterns can be selected on permanent mount minibars by
touching the yellow wire to the red power wire for less than a sec-
ond. Contacting the yellow and red wires for longer than a second
toggles to the preceding flash pattern. The 5590-VM and 5590-VM
models have flash pattern select via a momentary switch on the
cigarette plug.
Flash Pattern Syncing:
The 5590 permanent mount models sync with other compatible
ECCO products via the blue wire:
1. Determine the desired style of flash pattern for each unit and
set each unit individually (without the BLUE wires connected
together) to avoid confusion. It is also strongly recommended that
the same style of flash pattern be used on all units to produce the
most effective warning pattern. (NOTE: Phases A and B for each
style of flash pattern in the table denote the relative timing
between units connected in a synchronizing installation. To
operate simultaneously, each unit must be set to the same phase
(A + A or B + B); to operate alternately, units must be set to have
the opposite phase (A + B or B + A)).
2. Connect the BLUE (SYNC) wires together and check that the
units are flashing in a synchronized manner as expected. If a
pattern on one module appears to be wrong, the YELLOW
(PATTERN SET) wire can be used to cycle forward or backward
on that individual unit until the correct pattern is selected.
Note: This will only change the pattern in the one unit and will
not affect the other units connected to the BLUE (SYNC) wire.
3. If the blue wire is unused, leave unconnected and insulated.
Flash Pattern Chart
Phase
FPM
A
75
B
A
75
B
A
130
B
A
65
B
A
65
B
A
75
B
A
75
B
150
150
150
150
150
150
120
150/75
70
5590
SAE J845
Title
class 1
13
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Page 4 of 5

Publicidad

Tabla de contenido
loading

Tabla de contenido