If the safety thermostat is tripped, the appliance
has to be restored to the initial working condi-
tions as follows.
Press button (A) located under the equipment,
1)
to turn the electrical power supply back on
again.
To make the connection, connect the mains
line to the appliance's connection pipe, fi tting a
shut-off tap(A), to allow the water supply to be
cut off when necessary. Easily accessible fi lters
must be fi tted downstream of the tap.
Caution - Warning
The appliance must be supplied with drin-
king water having the characteristics shown
in the table.
GB
Description
Pressure
pH
Conductivity
Hardness
Salt and metallic
ion content
Chlorides
Sulphates
Iron
Copper
Manganese
3301460_inst_GB_rev.2
RESETTING THE APPLIANCE
WATER CONNECTION
Value
150÷300 kPa (1,5÷3 bar)
(*)
7÷7.5
<200 mS/cm
9÷13°C (5÷7°d, 6.3÷8.8°e,
90÷125 ppm)
<30 mg/l
<40 mg/l
<0,1 mg/l
<0,05 mg/l
<0,05 mg/l
A
A
(*) If the intake pressure exceeds 3 bar fi t a pressu-
re reducer.
- 12 -
ENGLISH