Flush installation
Install Appliance
Electrical Installation
All model ovens on the front cover are dual rated,
designed to be connected to either 208/240V AC,
60 Hz, 4 wire, single-phase power supply.
Model
HBE5453UC
The electrical supply should be a 4-wire single-phase AC.
Install a suitable conduit box (not furnished). An
appropriately-sized, UL-listed conduit connector must be
used to correctly attach the conduit to the junction box.
NOTICE: Local Codes may vary; installation, electrical
connections and grounding must comply with all
applicable local codes.
If local codes permit grounding through the electrical
supply neutral, connect both the white neutral wire and
the bare ground wire from the oven to the white neutral
electrical supply wire.
Dedicated circuit required
20 AMP
*
Flush installation requires a
21
/
" (557 mm) wide x 22
15
16
baseplate underneath the unit body.
** Flush installation under the counter requires a top
cleats
/
" (9 mm) high x 21
3
8
This part of furniture must be present, straight and
have no gap with the lateral parts.
CAUTION
9
The appliance must be disconnected from the
▯
power supply during all installation work.
The appliance must only be connected with the
▯
power cable provided.
Protection against contact must be ensured by
▯
the installation.
Electrical Connection
The four-wire connection is preferred, but where local
codes permit, the three wire connection is also
acceptable.
WARNING
9
When connected to a 4 or 5-wire, 120/208-Volt 3-
phase power supply, the phase C conductor is not
required for the operation of the appliance.
/
" (5 mm) high x
3
16
/
" (560 mm) deep
1
16
/
" (557 mm) wide.
15
16
7