Measured value
in hPa
only display switch!!
Selection of
measuring range
20 mg/l
60 mg/l
200%Sat 600% Sat
400 hPa
1200 hPa
Feedforword control
to PID controller
Off; lin = linear
Basic = basic load
Selection of
value pair in table
1
1 ... no. of value pairs
assign
O333
Enter 20mA value
10.000 mg/l; 0...20 mg/l
100.0%SAT; 0...200%SAT
200 hPa;
0...400hPa
40.0 °C;
-10...60 °C
O313
Activate
alarm contact
yes; no
Setting of maximum
permissible limit
violation period
(below limit)
480 min; 0...2000 min
126
Measured value
Measured value
Current input in %
Sensor signal in nA / mV
A6
Feedforward control
gain = 1 at
50%
0 ... 100%
Z6
Z7
Entry of x-value
Entry of y-value
(measured value)
(current)
0.000 mg/l;0...20 mg/l
0.0
; 0...200
%SAT
%SAT
0 hPa;
0...400 hPa
0.00mA; 0...20.00mA
O334
Activate error current
Automatic start of
for previously set
cleaning function
error
no; yes
no; yes
F6
F7
Setting of maximum
Setting of
permissible limit
limit value
violation period
1.000 mg/l;
50.0 %SAT; 0...200%SAT
(upper limit)
20 hPa;
240 min; 0...2000 min
P6
P7
Measured value
Current input in mA
Table status o.k.
yes; no
O335
O336
Selection "next error"
or return to menu
Next=next errror
<--- R
F8
F9
0...20 mg/l
0...400 hPa
P8
Liquisys M COM223/253
Field for customer
settings
A0027495-ES