WEG MW500 V1.5X Referencia Rápida De Los Parámetros, Alarmas Y Fallas página 12

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Description
Param.
P0263 DI1 Function
P0264 DI2 Function
P0265 DI3 Function
P0266 DI4 Function
P0267 DI5 Function
P0268 DI6 Function
P0269 DI7 Function
P0270 DI8 Function
Quick Reference of Parameters, Alarms and Faults
Adjustable
Range
0 = Not Used
1 = Run/Stop
2 = General Enable
3 = Quick Stop
4 = FWD Run
5 = REV Run
6 = Start
7 = Stop
8 = Clockwise Rotation Dir
9 = LOC/REM
10 = JOG
11 = Increase E.P.
12 = Decrease E.P.
13 = Multispeed
14 = 2
Ramp
nd
15 = Not Used
16 = Not Used
17 = Not Used
18 = No Ext. Alarm
19 = No Ext. Fault
20 = Reset
21 = SoftPLC
22 = Manual/Auto PID
23 = Not Used
24 = Disable Flying Start
25 = Not Used
26 = Program. Off
27 = Load User 1
28 = Load User 2
29 = PTC
30 = Not Used
31 = Not Used
32 = 2
Ramp Multispeed
nd
33 = 2
Ramp E.P. Ac.
nd
34 = 2
Ramp E.P. De.
nd
35 = 2
Ramp FWD Run
nd
36 = 2
Ramp REV Run
nd
37 = Start / Inc. E.P.
38 = Dec. E.P. / Stop
39 = Function 1 Application
40 = Function 2 Application
41 = Function 3 Application
42 = Function 4 Application
43 = Function 5 Application
44 = Function 6 Application
45 = Function 7 Application
46 = Function 8 Application
See options in P0263
See options in P0263
See options in P0263
See options in P0263
See options in P0263
See options in P0263
See options in P0263
Factory
User
Properties Groups
Setting
Setting
1
cfg
8
cfg
20
cfg
9
cfg
0
cfg
0
cfg
0
cfg
0
cfg
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
MW500 | 13

Publicidad

Tabla de contenido
loading

Tabla de contenido