CABINET CONSIDERATIONS AND COUNTERTOP CUTOUT
Dimension requirements in Figs. 1
& 2 are for combustible surfaces.
When the surface is protected by a
material listed by UL as a Floor
Protector and Wall Shield and is
covered with not less than No. 28
MSG sheet metal, 0.015-inch
stainless steel, or 0.024-inch
aluminum or copper, it is considered
noncombustible
and
dimensions may be reduced. For a
noncombustible surface over the
cooktop, the minimum clearance is
24" rather than 30".
Instructions are based on
standard American cabinets 36"
high x 24" deep with a 25"
countertop.
Provide approximately a 10-
square-inch opening in the toe
kick area or other cabinet area
for adequate air inlet to the
cabinet.
Figure 2
Cutout Dimensions are Underlined
Figure 1 – Installed Dimensions (from cooktop edges)
some
Dimensions are minimum clearances to combustible materials
NOTICE: All measurements
given in Figures 1 and 2 have to
be precisely followed. If non-
standard cabinets are used,
make sure they are installed with
minimum dimensions shown in
Fig. 1 and Fig. 2.
Cooktop to front of countertop – 1-1/4" minimum
Cooktop Depth
PAGE 2
Plan the installation of the unit so
that the power cord, gas shut-off
valve and gas pressure regulator are
accessible from the front of cabinet.
If a drawer is installed directly under
the cooktop, its depth (front to
back) should be no greater than 15".