Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

12.1 - WIRING DIAGRAM

Terminals
Description
PE, L, N
230Vac power line. Take extra
care to fasten the 3 cables to
each of the 3 terminals.
N1 QG1
Traffic lights supply
N.O. K1
Red traffic light
N.C. K1
Green traffic light
4
Barrier opening N.O. contact
5
Barrier closing N.O. contact
6
Open common contact
7
Close common contact
8
Stop N.C. contact
9
Stop common contact
10
Barrier end stroke N.O. contact
(1) The station is disabled if contact 12-13 is closed. It is used, for instance, to comply with a give way sig-
nal.
(2) Open collector 50mA 24V output. It is activated when the barrier is opened following an accepted
transit request (valid or correctly collected ticket, valid season ticket). This output is used for the Sacs
space counting system (CAPACITY KIT).
(3) Open collector 50mA 24V output. It is activated when the detection loop is triggered.
Termi-
Description
nals
11
Barrier end stroke common
contact
(1)
Station disabling contact
12
(1)
Station disabling contact
13
(2)
Transit in progress contact
14
(2)
Transit in progress contact
15
Transit request contact
(3)
16
(3)
Transit request contact
17
18
Detection loop
19
Detection loop
20
Safety loop
21
Safety loop
41 - Espas 20I