05617 TotalPure 2000 Ozone
Ozone production: 100 g/hour
Rated power <= 4. 8 W
Range of variability (production deviation): 100 mg/h +/- 1 mg
Ozone saturation curve: Highest peak after 1 hour of uninterrupted use.
Ozone decomposition curve: In 50 cubic meters, temperature 20 ºC, 5 minutes after starting, the ozone
concentration can kill bacteria. After 1 hour of operation it reaches the highest level of concentration,
1 mg/L. After 40 hours, open the window to ventilate the room and to allow the ozone concentration
to disperse into the room (5-10 minutes). In a normal closed room, it will take 1-2 hours for the ozone
to dissipate.
Maximum inmission levels: 1 mg/L
Materials not suitable for concentration level generated by the unit: Natural rubber.
Ozone generator classification: Type C ozone generator. Ozone generator for direct and indirect
discharge that does not include dilution system or production automatic control mechanism.
Made in China | Designed in Spain