9 Maintenance and cleaning
9.1 Maintenance and cleaning intervals
The specified intervals are standard values and refer to single-shift operation. We recommend recording the
inspections. The date of the inspection, the detected defects and the name of the inspector must be observed.
Daily
Weekly
Monthly
After approx. 800
operating hours
After two carbon brush
replacements
9.2 Emptying the dust collecting drawer
W
Health risk caused by inhaling harmful dust
Improper emptying of the dust collecting drawer can lead to harmful dust and debris penetrating the
ambient air. It can harm the respiratory tract if inhaled.
► Empty the dust collecting drawer into a dust collecting bag immediately after removal.
► Do not clean the device with compressed air.
From June 2021
EN - 16
► Empty the dust collecting drawer.
9.2 Emptying the dust collecting drawer on page EN-16
► Check the operating hours meter.
► Check device for visible damage.
► Carbon brushes must be replaced only by a qualified electrician.
9.4 Replacing the carbon brushes on page EN-19
► Turbines must be replaced only by a qualified electrician.
9.3 Replacing filler cartridges on page EN-17
WARNING
xFUME
Loosen the star screws on the dust collecting
1
drawer.
Empty the dust collecting drawer into a dust
2
collecting bag.
Close the dust collecting bag and dispose of it in
3
accordance with local regulations.
12 Disposal on page EN-23
Reassemble in the reverse order and ensure that
4
the star screws are tightened by hand.
®
ADVANCED