®
xFUME
ADVANCED
10 Faults and troubleshooting
W
Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first
use. It can damage the respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Use the device only in rooms with sufficient ventilation.
► Ensure that all seals on the device are free from dirt and debris.
► The provided filtration system must be used when operating the device.
► The dust collecting drawer must be closed when operating the device.
► Do not open the dust collecting drawer until at least one minute has passed since the device was
► Keep the device closed during operation and during the cleaning process.
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner
► Observe the documentation for the welding components.
► Contact your retailer or ABICOR BINZEL in the event of questions or problems.
Tab. 3
Faults and troubleshooting
Fault
Extraction volume too low.
External extraction system
does not start.
Dust escapes from the dust
collecting drawer.
Filter cleaning does not work. Compressed air supply is faulty.
Service LED illuminates
continuously.
From June 2021
WARNING
switched off.
or a damp cloth.
Cause
Filter elements saturated.
Dust collecting drawer not properly sealed.
Extraction hose blocked.
Extraction hose defective.
The quick lock is not mounted correctly.
The star screws are not mounted correctly.
The power supply is faulty.
Electrical components defective.
The carbon brushes are defective.
Automatic mode, current clamp is not mounted
correctly.
Dust collecting drawer not properly sealed.
Dust collecting drawer full.
The quick lock is not mounted correctly.
The star screws are not mounted correctly.
Filter cartridges are defective/saturated.
10 Faults and troubleshooting
Troubleshooting
► Replace the filter cartridges.
9.3 Replacing filler cartridges on
page EN-17
► Check and install correctly.
9.2 Emptying the dust collecting drawer
on page EN-16
► Clean the extraction hose.
► Replace the extraction hose.
6.1 Attaching the extraction hose on
page EN-12
► Mount the quick lock correctly.
► Tighten the star screws by hand.
► Check and replace as needed, or contact
customer service.
9.4 Replacing the carbon brushes on
page EN-19
► Mount the current clamp properly.
7 Operation on page EN-14
► Check and install correctly.
9.2 Emptying the dust collecting drawer
on page EN-16
► Empty the dust collecting drawer.
9.2 Emptying the dust collecting drawer
on page EN-16
► Mount the quick lock correctly.
► Tighten the star screws by hand.
► Check and replace if necessary.
► Replace the filter cartridges.
9.3 Replacing filler cartridges on
page EN-17
EN - 21