Installing The Pneumatic System - Festo DSMI-B Serie Instrucciones De Utilizacion

Ocultar thumbs Ver también para DSMI-B Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
DSMI-...-B

Installing the pneumatic system

Note
Uncontrolled operation without positioning controller and without additional
external one-way control valves will destroy the DSMI, even if it is pressurised
only once for test purposes.
• Note that the DSMI does not have any flow control for the pneumatic
connections.
The DSMI may only be used without external one-way control valves in
electronically controlled operation in combination with a positioning
controller.
For electronically closed-loop control of the DSMI in combination with a
positioning controller:
Note
Special installation specifications apply to the electronically controlled
operation.
• To install the pneumatic system, please observe the instructions in the
descriptions of the positioning controller.
Connect the tubing of the DSMI with the
proportional directional control valve
according to the colour codes of the con-
nections.
– Black release ring (looking at the stop
lever, it swivels in clockwise direction).
– Blue release ring (looking at the stop
lever, it swivels in anticlockwise
direction).
32
Fig. 17
Festo DSMI-...-B 1210b English

Publicidad

Tabla de contenido
loading

Tabla de contenido