DSMI−...−B

Installing the pneumatic system

Note
Uncontrolled operation without positioning controller and without additional
external one−way control valves will destroy the DSMI, even if it is pressurised
only once for test purposes.
· Note that the DSMI does not have any flow control for the pneumatic
connections.
The DSMI may only be used without external one−way control valves in
electronically controlled operation in combination with a positioning
controller.
For electronically closed−loop control of the DSMI in combination with a
positioning controller:
Note
Special installation specifications apply to the electronically controlled
operation.
· To install the pneumatic system, please observe the instructions in the
descriptions of the positioning controller.
·
Connect the tubing of the DSMI with the
proportional directional control valve
according to the colour codes of the
connections.
Black release ring (looking at the stop
lever, it swivels in clockwise direction).
Blue release ring (looking at the stop
lever, it swivels in anticlockwise
direction).
32