7
Technical Data
Power Supply: ............................ 1 x 9V battery (alkaline preferred)
Sensor:....................................... Solid state semi conductor
Sensitivity: .................................. <50ppm methane
Indicators: .................................. Audible: Adjustable tic rate
Warm-up: .................................. 10 seconds
Response Time: .......................... Instantaneous
Duty Cycle:................................. Continuous
Battery Life:................................ 5 hours typical use
Dimensions (HxWxD): ................. 8"x 4" x 1.5", 205mm x 100mm x 36mm
Weight:...................................... 15 oz / 460 gm
Probe Length:............................. 18 inches / 460 mm
Operative: .................................. 0-50
Protection against Electric Shock
(in accordance with EN 61010-1 : 1993)
This instrument is designated as Class III, SELV.
Please note: In this equipment the used batteries are to be disposed in accordance with the
current laws and local guidelines.
6
Accessories
The relevant accessories and an order form can be found from Page 70 onwards.
7
Disposal
Components of the unit are recyclable material and should be put to recycling. For this purpose
registered and certified recycling companies are available. For an environmentalfriendly disposal
of the non-recyclable parts (e.g. electronic waste) please contact your local waste disposal
authority.
For EU countries only:
Do not dispose of electric tools with domestic waste. In accordance with European
Directive 2002/96/EC on waste electrical and electronic equipment and its
implementation as national law, electric tools that are no longer serviceable must be
collected separately and utilised for environmentally compatible
Visual: Flashing LED
o
o
C / +32-122
F
ENGLISH
recycling.
9