NOTE:
To be able to assemble the parts of the coupler, the diameter of the power
cable must be between 5.5 mm and 7 mm.
1
Fig. 10: RJ45 coupler design
1
End nut
2
Sealing ring with inside diameter of
3
Seal body
4
Connector (shown here ready dressed)
Internal conductors
4a
Shielding/sheathing
4b
5
Coupler
Ridge
5a
 The connector has not yet been connected to the cable.
1. First slide the end nut (1), the sealing ring (2) and then the seal body (3)
over the cable.
2. Connect the contacts of the cable to pins (4a, 4b) of the coupler.
3. Carefully slide the flexible grips of the seal body (3) over sealing ring (2).
Slide the seal body over the sealing ring until the sealing ring is fully en-
closed by the grips.
4. Slide the seal body (3) over the connector (4).
70
3
2
4b
SignalShark 3330 Outdoor Unit
4
4a
5a
5.5 to 7 mm