Broan-NuTone HLB6 Instrucciones De Montaje

Broan-NuTone HLB6 Instrucciones De Montaje

Ventilador para montaje en línea broan elite y nutone premier
Ocultar thumbs Ver también para HLB6:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

MODEL HLB6
IN-LINE BLOWER
For use with Broan Elite and NuTone Premier Hoods.
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service discon-
necting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to
a GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
B. Always turn hood ON when cooking at high heat or when
flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Pepper-
corn Beef Flambe').
C. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
D. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOW-
ING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - vio-
lent steam explosion will result.
!
FOR DOMESTIC COOKING ONLY
WARNING
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. If ventilator is installed in an unconditioned space (such as
an attic): Surround the ventilator with thermal insulation - to
minimize possible condensation.
4. Please read specification label on product for further informa-
tion and requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
• "TYPICAL INSTALLATION"
This section shows a common installation.
- Mounting (New Frame Construction)
- Mounting (Existing Frame Construction)
- Mounting Using Hanger Kit (included)
- Ducting (straight-through blower discharge)
- Wiring
• "MOUNTING OPTIONS"
• "WIRING OPTIONS"
- Wiring Plate Position
• "DUCTING OPTIONS"
- Blower Discharge Positions
- Ducting (vertical blower discharge)
• "USE AND CARE"
• "SERVICE PARTS"
• "WARRANTY"
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 4.
Page 1
!

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan-NuTone HLB6

  • Página 1 Page 1 MODEL HLB6 IN-LINE BLOWER For use with Broan Elite and NuTone Premier Hoods. READ AND SAVE THESE INSTRUCTIONS FOR DOMESTIC COOKING ONLY WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- 4. Use an extinguisher ONLY if: JURY TO PERSONS, OBSERVE THE FOLLOWING: A.
  • Página 2: Typical Installation

    Page 2 TYPICAL INSTALLATION TYPICAL INSTALLATION MOUNTING (New Frame Construction) MOUNTING USING HANGER KIT (included) 10” ROUND DUCT 4½” X 18½” Mounting brackets TO 10” ROUND HANGER factory-shipped in TRANSITION KIT BOLT position for ½” & WASHER ceiling material. EXTENSION CEILING SPRING JOIST...
  • Página 3: Wiring Options

    Page 3 WIRING WIRING OPTIONS BLACK WIRING PLATE POSITION TOP / BACK BLACK OF HOUSING GROUND TO WIRING PLATE VERTICAL POWER CABLE WIRING CONNECTION PLATE 120 VAC HORIZONTAL POWER LINE IN CABLE CONNECTION WHITE (from range WHITE Wiring plate mounts to side or top of housing. hood) Ventilator can be wired from outside of housing.
  • Página 4: Service Parts

    BROAN-NUTONE ONE YEAR LIMITED WARRANTY Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
  • Página 5 Página 5 MODELO HLB6 VENTILADOR PARA MONTAJE EN LÍNEA Por uso con campanas de Broan Elite y NuTone Premier. LEA Y CONSERVE ESTAS INSTRUCCIONES PARA COCINAR EN CASA SOLAMENTE ADVERTENCIA ADVERTENCIA una explosión de vapor violenta. PARA REDUCIR EL RIESGO DE INCENDIO, GOLPE ELÉCTRICO, O LESIÓN A PERSONAS, OBSERVE LO SIGUIENTE: 4.
  • Página 6: Instalación Típica

    Página 6 INSTALACIÓN TÍPICA INSTALACIÓN TÍPICA MONTAJE EL USAR KIT DE SUSPENDER MONTAJE ( Estructura nueva ) (incluido) CONDUCTO REDONDO Abrazaderas de montaje, DE 25,4 cm (10 po) enviadas de fábrica en TRANSICIÓN posición para montarse en 11,4 X 47 a 25,4 cm TORNILLO Y una vigueta de ½”...
  • Página 7: Opciones De Montaje

    Página 7 CABLEADO OPCIONES PARA LA CONEXIÓN ELÉCTRICA NEGRO A PARTE SUPERIOR/ NEGRO POSTERIOR DEL COLOCACIÓN DE LA ENTO ALOJAMI PLACA DE CONEXIONES TIERRA A LA PLACA DE CONEXIONES CONEXIÓN PLACA DE VERTICAL DEL CONEXIONES CABLE DE ALIMENTACIÓN BLANCO LÍNEA DE CONEXIÓN ENTRADA DE HORIZONTAL...
  • Página 8: Uso Y Cuidado

    (c) describir el defecto en el producto o pieza. Al solicitar servicio bajo la garantía, usted debe presentar evidencia de la fecha de compra original. En los Estados Unidos, llame: Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
  • Página 9 Page 9 MODÈLE HLB6 VENTILATEUR MONTAGE DANS LIGNE Pour usage avec Broan Elite et NuTone Premier hottes de cuissine. LIRE ET CONSERVER CES INSTRUCTIONS POUR USAGE DOMESTIQUE SEULEMENT AVERTISSEMENT AVERTISSEMENT 3. N’UTILISEZ JAMAIS D’EAU, incluant les linges à vaisselles ou serviettes POUR RÉDUIRE LE RISQUE D´INCENDIE, DE CHOC ÉLECTRIQUE OU DE...
  • Página 10: Installation Typique

    Page 10 INSTALLATION TYPIQUE INSTALLATION TYPIQUE MONTAGE (Construction en cours) MONTAGE EN UTILISANT LE KIT DE CINTRE (inclus) CONDUIT TRANSITION CIRCULAIRE 4½ X 18½ au 10 po Supports DE 10 po (25,4 cm) (11,4 x 47 au 25,4 VIS ET préassemblés pour cm) circulaire RONDELLE DE...
  • Página 11: Options De Montage

    Página 11 CÂBLAGE OPTIONS DE CÂBLAGE POSITION DE LA NOIR AU DESSUS / NOIR PLAQUE DE CÂBLAGE ARRIÈRE DU BOÎTIER FIL DE TERRE À BRANCHEMENT PLAQUE DE CÂBLAGE DU CÂBLE D’ALIMENTATION PLAQUE À LA VERTICALE CÂBLAGE BRANCHEMENT DU ENTRÉE CÂBLE D’ALIMENTATION 120 VCA À...
  • Página 12: Utilisation Et Entretien

    Au temps de demander le service sous garantie, vous devez présenter une preuve de la date d’achat original. Aux E.U., comuniquez avec: Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453) Au Canada, comuniquez avec: Broan-NuTone Canada, 1140 Tristar Drive Mississauga, Ontario L5T 1H9 (905-670-2500)

Tabla de contenido