STEP 2B
CAUTION:
Avoid potential personal injuries and property damage!
Mount the wall plate
12
Minimum solid concrete thickness: 8 in. (203 mm)
Minimum concrete block size: 8 x 8 x 16 in. (203 x 203 x 406 mm)
Minimum horizontal space between fasteners: 24 in. (610 mm)
1.
Position the wall plate
IMPORTANT
: FOR EXTENDED WALL PLATES: You MUST install 2 lag bolts
a minimum of 16 in. (406 mm) out from center, for a minimum of 6 lag bolts total.
NOTE: For assistance in determining wall plate location, see Height Finder at sanus.com.
2.
Drill six pilot holes using a 3/8 in. (10 mm) diameter drill bit.
IMPORTANT
: Pilot holes must be drilled to a depth of 3 in. (75 mm). Never drill into the mortar between blocks.
1
16 in.
(406 mm)
12
Solid Concrete or Concrete Block Installation
directly onto the concrete surface
on the wall at your desired height. Level the wall plate and mark the hole locations.
11
Min.
20
into the center (top and bottom) of wall plate
2
19
3 in. (75 mm)
3/8 in.
(10 mm)
, then
19

Publicidad