Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14

• Charging curve :

The GYSFLASH 6.24 uses a 7 step charging curve which guarantees optimal performance for your battery.
U
I
Analysis
<1s
CHARGE
OK
1
Step
: Analysis
Analyses the battery state (charge level, polarity inversion, wrong
battery...)
2
Step
: Recovery (
Damaged elements recovery due to an extended deep discharge
algorithm
3
Step
: Test
Sulfated battery test
4
Step
: Desulfation (
Battery desulfation algorithm.
• Estimated charge time
Battery capacity
Charging time 20% >>> 80%
• Protections :
The GYSFLASH 6.24 has comprehensive safety features to protect it against short-circuits and polarity reversals. It
has an anti-spark feature which prevents sparks whilst connecting the device to the battery. This charger has double
insulation and is safe to use with the battery in situ as it will protect the vehicle's on-board electronics.
The GYSFLASH 6.24 is fitted with an integrated temperature probe that ensures that the charging current is adapted to the
ambient temperature, for an optimal charging performance.
8
1
2
3
Recovery
Test
Max 5h
<1s
3A-0.5A
/
2A-0.5A
*
7.9V /
15.8V /
2Ah
8Ah
2h
6h
GYSFLASH 6.24
4
5
Desulfation
Charge
Max 12h
Max 20h
5
Step
: Charge (
Fast charge with maximum current that can reach 80% charge
level.
)
*
6
Step
: Absorption (
Constant voltage charge to reach a 100% charge level.
7
Step
: Maintenance/Floating charge
(
6.7V /
Maintains battery charge level at its maximum.
31.6V)
12Ah
20Ah
50Ah
125Ah
9h
3h
6h
14h
6
7
Absorption
Floating
Max 8h
No limit
6A-0.8A
/
*
7.3V /
14.6V /
13.6V /
27.2V)
with « small battery » option active
*
20Ah
50Ah
100Ah
4h
9h
16h
EN
4A-0.8A
)
*
29.2V)

Publicidad

Tabla de contenido
loading

Tabla de contenido