8
INSTALLING THE INTELLIBRITE
FIXTURE (AFTER ELECTRICAL REQUIREMENTS ARE MET)
To install the IntelliBrite
1.
Switch off main electrical switch or circuit breaker, and the switch which
operates the IntelliBrite underwater light.
Route light cable through conduit to Junction Box, leaving at least 48 in (122 cm) of
cable at the light fixture to coil around the light (this allows the light to be serviced
after the pool is filled with water). See Figure 3 (USA), and Figure 4, (Canada)
below.
Figure 3, USA.
Junction/Deck Box must have a water tight bushing.
To GFCI, Circuit
Breaker and
Power Source.
Rigid
Conduit
GFCI and/or Transformer must be
located 3 m or more from pool wall.
(See *NOTE above.)
Figure 4, Canada.
INTELLIBRITE
5G Pool and Spa Lights Installation and User's Guide
®
®
Pool Light and Spa Light fixture:
48 in (121.92 cm) minimum
4 in (10.16 cm) minimum
#8 AWG Bonding Connector
(located on outside of niche)
Pilot screw at
12 O'Clock position
#6 AWG Bonding Connector
(located on outside of niche)
®
5G POOL AND SPA LIGHT
16 in
40.64 cm
3 m
204 mm
406 mm
8 in (20.32 cm)
18 in (42.72 cm) minimum
to top of lens
11.50 in (29.21 cm) min.
Wrap around 48 in (122 cm)
of light cable around fixture
Water surface level
600 mm max. to the
centerline of the Lens.
Pilot Screw at 12 o'clock position
Concrete must be cut
back around Niche to
allow for a compacted
plaster seal.
292 mm
Coil 1.22 m of light
cable around fixture.