Installing The Intellibrite Light Assembly, New Gasket/Uni-Tension Wire Clamp - Pentair INTELLIBRITE 5G LIGHT Guía De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

16
3.
INSTALL UNI-TENSION WIRE CLAMP: With the hook ends of the circular uni-
tension clamp pointing down, spread the clamp and place it in the "U" recesses
of the locking levers. Be sure the hook ends of the clamp are located between
the pair of locking levers as shown below and that the wire clamp is properly
engaged with all of the lock levers.
4.
Place a cloth on the ground to protect the lens. Turn the light over so the lens
is resting on the cloth. Be sure the orientation of the wire clamp and the bolt
connection is positioned at 45°.
5.
Tighten the bolt and nut until the distance between the ends of the clamp equals
1/4 in (0.64 cm) or less.
"TOP" label
(use to align light
housing with pilot
screw on face
PILOT
SCREW
Position the wire clamp (nut and bolt) about 45°
between the PILOT SCREW and BOLT/NUT.
INTELLIBRITE
5G Pool and Spa Lights Installation and User's Guide
®
Continue on next page.
PILOT SCREW
(12 o'clock)
"W" ON LENS
BRASS NUT
Align letter "W" ("WIDE"
angle) on lens/gasket
with pilot screw hole
on face ring and brass
nut
For "NARROW" angle
light beam, rotate "N"
to 12 o'clock position
1/4 in (0.64 cm) or less
Uni-tension
wire clamp
Lock
lever

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido