Table 1 - I/O terminal connector block:
Pin Function
1
Output A
2
Output B
3
Digital Input 1
4
Digital Input 2
5
RS-485/422-A
(non-inverting)
6
RS-485/422-B
(inverting)
7
GND
Table 2 - LED indicators:
LED Function
Color
1
Network
Green
Amber
Red
Unlit
2
Status
Green
Amber
Red
3
Heater
Green
Red
4
Power
Green
Amber
Description
On the external device output terminals (A and B), there is no distinc-
tion between positive and negative (+ and -). The terminals use a pho-
tocoupler and are electrically isolated from the other internal
circuitry.
The maximum load should not exceed 100mA and the maximum volt-
age should be not more than 50V DC. Note: Connecting AC to the out-
put will damage the unit.
Connect to GND to activate, or leave floating (or unconnected) to
deactivate.
A half-duplex RS-485/422 interface for controlling auxiliary equip-
ment.
Ground.
Description
Steady for connection to 100 Mbit/s network. Flashes for network
activity.
Steady for connection to 10 Mbit/s network. Flashes for network activ-
ity.
Flashes rapid red, together with the Status indicator, for hardware
error.
No connection.
Shows steady green for normal operation.
Shows steady amber during reset to factory default or when restoring
settings.
Slow flash for failed upgrade. Rapid flash, together with the Network
indicator, for hardware error.
Steady green when the power connected is sufficient for the heater
i.e. (12V DC min 20W or 24V AC min 25VA)
Insufficient power for the heater.
Normal operation.
Flashes green/amber during firmware upgrade.
AXIS 225FD Installation Guide