03.05 Water outlet
Steam generator outlet should be connected with water outlet by siphon (made of material resistant to high temperature)
to allow inspection and cleaning. Collecting funnel should be installed minimum of 200mm under the steam generator
drain nozzle.
03.06 Piping / empty pipes
Description
Temperature sensor
Wall lamp
Control panel
Supply air blower
Fragrance dosing pump
03.07 Steam pipe
Minimum cross-section tube of 35mm should be considered for steam connecting. Steam connection cables from steam
generator to steam jet should be made of copper or stainless steel with appropriate thermal insulation . The exact steam
jet position is presented in the steam cabin drawings. Steam supply cable cannot have closing valve or cut-off valve.
Furthermore, it must be protected against external impact (bending and deformation). Due to the technical requirements
for cable connections only 45 degrees elbow can be used.
GB
03.08 Air supply blower
Air supply blower should be connected with steam jet with a pipe (HT DN 40 pipe). The attached installation instructions
for air supply blower should be followed during installation.
20
Empty pipe should be provided
Yes
Yes
Yes
Yes
Yes
Supply or connecting cable
2 x 0,5 mm
2
2 x 1,5 mm
2
4 x 0,25 mm
2
3 x 1,5 mm
2
2 x 1,5 mm
2