Electrical Connection; Wiring Diagram - Taurus GI3EB Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1

ELECTRICAL CONNECTION:

This appliance must be earthed.
This appliance is design ed to be connected to a 220-240 V, 50-60 Hz electricity supply.
The wires in the mains lead are coloured in accordance with the following code:
Green/yellow → Earth
-
Blue → Neutral
-
Brown → Live
-
The wire which is coloured green and yellow must be connected to the terminal which is
marked with the letter E or by the earth symbol.

WIRING DIAGRAM

When the power cord is damaged it must be replaced by the manufacturer to produce,
customer service agent or similarly qualified personnel.
GAS ADJUSTMENT:
Adjustment of mínimum level of the flame
1. Turn the taps down to mínimum.
2. Remove the knob from the tap and place a small bladed screwdriver in the
centre of the tap shaft.
3. The correct adjustment is obtained when the flame has a length of about 3-4
mm.
- For butane / propane gas, the adjusting screw must be tightly screwed in.
- Refit the control knob.
Make sure that the flame does not go out by quickly turning from maximum flow to
minimum flow. If it does then remove the control knob and make further
adjustments to the gas flow, testing it again once the adjustment has been
made.

Publicidad

Tabla de contenido
loading

Tabla de contenido