Maintenance And Troubleshooting; Routine Maintenance Operations; Troubleshooting - Runtal 40016512 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 102
COPY/PASTE FUNCTION (help for programming)
Long press on
P1P2: back to
previous day,
copies the current
boost
daily programme.
mode
Long press on
mode: move to
next day, copies
the current daily
boost
programme.
mode
74
boost
mode
boost
mode
boost
mode
boost
8. Maintenance and troubleshooting tips

8.1 Routine maintenance operations

High-quality materials and surface treatment protect your appliance against corrosion and
impacts.
To maximise the service life of your appliance, we recommend you take the following precau-
tions:
- Never use abrasive or corrosive products on the outer surfaces of the appliance (except the
electrical parts); use warm, soapy water.
- For the casing of the control unit and the remote control, use a dry (solvent-free) cloth.

8.2 Troubleshooting

Despite all our efforts in manufacturing our products, you may encounter some easy-to-solve
operating failures. In this case, please consult the table below to find our suggested solution.
boost
Nonetheless, should you fail to solve the problem encountered, please contact your supplier's
after-sales service for assistance.
Problem
mode
The appliance is not
heating.
boost
40016512
11/2017
Diagnosis
Procedure
The temperature setting on the
Check the remote control is set to ask
remote control is incorrect.
the appliance to start heating (see
chapter 5.2).
The mixed appliance has not
Check the filling of the appliance (see
filled with water properly.
chapter 3.2).
The appliance is operated by a
See the programming unit manufac-
programming unit.
turer's manual.
The load shedder is enabled
Wait for load shedding to finish.
and has shut down heating on
the appliance.
The appliance has not be
Remove the batteries from the
paired with the remote control
remote control, wait a few seconds,
(the
icon is not displayed
then replace the batteries and pro-
on the remote control screen).
ceed with pairing (see chapter 4.1).
An open window detected
Turn off the window opening
(
icon flashes)
detection function (see chapter 5.5,
parameter 1).
The LED is flashing yellow:
Contact your installer.
default.