BEFORE CALLING
FOR SERVICE
_CHECK VENT indicator
is blinking
Exhaust system is too long or has
too many turns/restrictions.
_ This warning light is
not a dryer failure and is
not covered by the dryer
warrant,/. Contact a duct
cleaning service to set
up an appointment
to
have your exhaust system
cleaned and inspected.
The CHECK VENT
indicator remains active
(blinking) after clearing
the restriction in the
venting: .........
Dryer will not turn on
Partial blockage of the ductwork
due to lint buildup or other foreign
object.
The appliance
has detected a
restriction in the external dryer
venting.
After clearing the restriction, the
CHECK VENT system requires
multiple, consecutive cycles to
determine that the performance
value
has improved before the
CHECK VENT indicator is reset.
Power cord is not properly plugged
in,
House fuse is blown, circuit breaker
has tripped, or power outage has
occurred.
Install a shorter or straighter duct run. See the
Installation Instructions for details.
Ductwork should be checked/cleaned
immediately.
Dryer can be used in this condition, but drying
times will be longer and energy consumption will
increase.
See the CHECK VENT INDICATOR and CHECK
VENT OPERATION sections for details regarding
this function.
If the CHECK VENT indicator remains active for
more than five cycles after the restriction has been
cleared, call for service.
Make sure that the plug is securely plugged into a
grounded outlet matching the dryer's rating plate.
Reset circuit breaker or replace fuse. Do not
increase fuse capacity. If the problem is a
circuit overload, have it corrected by a qualified
electrician.
Buttons are disabled or
CONTROL LOCI< function is
Pressand hold the CONTROL LOCK button for five
CL shows in display
engaged,
seconds to activate or deactivate the function.
Light does not turn on
Dryer has been of? for more than
Pressthe PowER button to turn on the dryer, which will
"when door is opened
four
minutes and light is disabled,
enable the drum light.
Dryer does not heat
House fuse is blown, circuit breaker
has tripped, or power outage has
occurred.
Greasy or dirty, spots on
clothes
Drying time is not
consistent
Reset circuit breaker or replace fuse. Do not
increase fuse capacity. If the problem is a
circuit overload, have it corrected by a qualified
electrician.
Gas supply or service is turned of?
(gas models only).
Clean and dirty clothes are being
dried together.
Clothes
were not properly
cleaned
or rinsed before
being
placed
in the
dryer.
Heat settings, load size, or
dampness of clothing is not
consistent.
Stains on dried clothes could be stains that weren't
removed during the washing process. Make sure
that clothes are being completely cleaned or
rinsed according to the instructions for your washer
and detergent. Some difficult soils may require pre-
treating prior to washing.
The drying time for a load will vary depending on
the type of heat used (electric, natural gas, or LP
gas), the size of the load, the type of fabrics, the
wetness of the clothes, and the condition of the
exhaust duct and lint filter. Even an unbalanced
load in the washer can cause poor spinning,
resulting in wetter clothes which will take longer to
dry.
NOTE: Due to the design of electric dryers, it is
possible for a circuit problem to allow an electric
dryer to run without heat.
Confirm that the house gas shutoff and the dryer
gas shutoff: valves are both fully open. Even if gas
is not supplied to the dryer, it will run and no error
codes will display. Verify that other gas appliances
in the home are working normally.
Only use your dryer to dry clean items. Soil from dirty
clothes can transfer to the clean clothes in the same or
later loads.
3]