Key Dimensions And Specifications; Location Requirements; Choose The Proper Location; Clearances - KENMORE ELITE 796.6162 Serie Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

KEY DIMENSIONS
AND SPECiFiCATiONS
Description
Dryer
Dryer (Gas and Electric)
Electrical
Requirements
Refer to the rating
label
Gas Requirements _ NG:
4-10.5
inches WC
Gas Requirements _ LP:
8-13 inches WC
Dimensions
27 in. (W) X 29.4 in. (D) X 45 in. (H), 50 1/4 in. (D with door open)
68.6 cm (W) X 73.4 cm (D) X 114,1 cm (H), 12Z5 cm (D with door open)
Net Weight
Electric
: 135.2 lb. (61.3kg)
Gas : !38.9 lb. (63kg)
Drying
Capacity
IEC 7.3 cu. ft.
_Gas Models
Only
LOCATION
REQUIREMENTS
iMPORTANT: Read all installation
instructions
completely
before installing and operating
your dryer.
it is important
that you review this entire manual before
installing and using your dryer. It contains detailed
instructions concerning electrical
connections, gas
connections and exhaust requirements.
CHOOSE THE PROPER LOCATION
° Store and install the dryer where it will not be exposed
to temperatures below freezing or exposed to outdoor
weather conditions.
• Choose a location with a solid, level floor.
"If the dryer is being installed in a garage, place the
dryer at least 18 inches (45.7cm) above the floor.
"Properly ground the dryer to conform with all
governing codes and ordinances.
"To reduce the risk of electric shock, do not install the
dryer in damp or wet locations.
IMPORTANT= If you are installing your dryer in a
manufactured
or mobile home, please refer to the
Special Electrical Requirements for Mobile or
Manufactured
Homes section.
• Most installations require a minimum 5 1/2inch (14 cm)
clearance behind the dryer for the exhaust ducting.
° AHow minimum clearances of at least 1 inch (2.5 cm)
on the sides and back to minimize vibration and noise.
° Allowing additional
clearance for installation
and
servicing is recommended.
• Be sure to allow for wall, door, or floor moldings that
may increase the required clearances.
• Allow at least 21 inches (53.3 cm) in front of the dryer
to open the door.
L_J
21 l/4"
(54 cm)
/
1"--..I
1"
4"
(68.6 crn)
50 !/4"
(127.5 cm)
3 _¸_
,_
(7,6
cm) _
48 in._ i
(310 cm)
34 in, _
(155 cm) .
3"
v
(7.6 ¢m)
_
Closet Door Clearance
Requirements
Additiona|
instructions for closet installations:
The closet door must allow for sufficient airflow. Refer to the
diagram above for minimum vent opening requirements. A
Iouvered door is also acceptable.