Perceive PD Series Recessed Instructions
PACKAGING CONTENTS
Fixture housing assembly
ITEMS REQUIRED
(Purchase Separately)
Phillips Screwdriver
Flat Head Screwdriver
Wire Cutters
INSTALLATION
Fixture Installation/Wiring
1.
Remove product from packaging material. Do not lift
fixture by one end or pull on the end plates in any way.
Luminaire should be handled by both side rails.
2.
Install the luminaire into the ceiling T-grid system. Ensure
that the luminaire sits snuggly in T-grid system.
(Figure 1)
Figure 1. 
3.
The Grid-Lock feature is built into the end plates. Insert a
straight-blade screw driver into the slot on each tab and
rotate the tabs out ninety degrees, lay the fixture into the
grid, continue the rotation about thirty more degrees to
lock on the bottom edge of grid member "bulb." There is
no need to open the fixture to use this feature.
Figure 2. 
2
COOPER LIGHTING SOLUTIONS
Hammer
Safety Glasses
Wire Strippers
IB519135EN
Installation instructions
4.
Remove electrical access plate and remove necessary
knockouts from access plate for attachment of
electrical supply cable (Figure 3). Make necessary wiring
connections to driver AC line input. A Linear Disconnect
is provided to speed installation (Figure 4).
N
The fixture is compatible with 0-10V, STEP, DALI,
ote:
Lutron, and LV dimming. If installing dimming wires
follow your dimmer instructions for wiring to the
fixture.
Step 1
Step 2
Figure 3. 
Linear Disconnect
Black
White
Figure 4. 
5.
Replace electrical access plate and snap securely into
place. If required, install optional screw to lock the
access plate closed.
Standard Access Plate Installation
Step 1: To insert access plate, rotate until leading end is inside the
wireway (Figure 3).
Step 2: Fold into horizontal position and slide forward into locking
position.