Starting Operation - Würth AL 60-CV-LI Traducción Del Manual De Instrucciones De Servicio Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
OBJ_BUCH-2220-001.book Page 8 Tuesday, June 10, 2014 3:55 PM
Product Features
The numbering of the product features refers to the illustration
of the charger on the graphics page.
1 Battery pack*
2 Green battery charge indicator
3 Charging compartment
*Some accessories shown or described are not part of
the standard delivery scope of the product.
Tool Specifications
Battery Charger
Art. No.
Output voltage (automatic
voltage detection)
Charging current
Allowable charging
temperature range
Charging time for battery
capacity, approx.
– 1,3–1,5 Ah
– 2,0 Ah
– 2,6–3,0 Ah
– 4,0 Ah
– 5,0 Ah
Number of battery cells
Weight according to
EPTA-Procedure 01/2003
Protection class

Starting Operation

 Observe the mains voltage! The voltage of the
power supply must correspond with the data given on the
nameplate of the battery charger. Battery chargers
marked with 230 V can also be operated with 220 V.
Charging Procedure
The charging procedure starts as soon as the mains plug of
the battery charger is plugged into the socket outlet and the
battery 1 is inserted into the charging compartment 3.
Due to the intelligent charging method, the charging condition
of the battery is automatically detected and the battery is
charged with the optimum charging current, depending on
battery temperature and voltage.
This gives longer life to the battery and always leaves it fully
charged when kept in the charger for storage.
Flashing Battery Charge Indicator 2
Continuous Lighting of the Battery
Charge Indicator 2
AL 60-CV-LI
0700 816 XXX
allowable charging temperature range, and cannot be
charged for this reason. The battery is charged as soon as the
V
10.8 – 18
allowable charging temperature range is reached.
A
2.0
When the battery is not inserted, continuous lighting of
the battery charge indicator 2 indicates that the mains plug is
°C
0 – 45
inserted in the socket and that the battery charger is ready for
operation.
(80%)
100%
min
(35)
50
min
(50)
65
min
(60)
95
min
(95)
125
min
(120)
150
Cause
3 – 10
Continuous lighting of the battery charge
indicator 2
kg
0.5
No charging procedure possible
/ II
Battery not (properly)
inserted
Battery contacts
contaminated
Battery pack defective
Battery charge indicator 2 does not light up
Mains plug of battery
charger not plugged in
(properly)
Socket outlet, mains cable or
battery charger defective
Meaning of the Indication Elements
The charging procedure is signalled by a
flashing battery charge indicator 2.
Continuous lighting of the battery
charge indicator 2 indicates that the
battery is fully charged or that the tem-
perature of the battery is not within the
Troubleshooting – Causes and
Corrective Measures
Corrective Measure
Properly insert battery into
battery charger
Clean the battery contacts
(e.g. by inserting and
removing the battery several
times) or replace the battery
Replace the battery
Insert mains plug (fully) into
the socket outlet
Check the mains voltage;
have the battery charger
checked by an authorised
after-sales service agent for
Würth power tools
8