6. Wiring.
WARNING: Turn off circuit breakers to current fixture
from breaker panel and be sure operating light switch
is turned to the OFF position.
CAUTION: Be sure outlet box is properly grounded and
that a ground wire (GREEN or Bare) is present.
Make sure all electrical connections comply with Local
Codes or Ordinances and the National Electrical Code. If
you are unfamiliar with electrical wiring or if the
house/building wires are different colors than those
referred to below, please use a qualified electrician.
Note: Excess lead wire length from the fan can be
cut to the desired length and then stripped.
When downrod is secured in place on the hanging
bracket, electrical wiring can be made as follows:
Connect BLACK and BLUE wire from fan to BLACK
wire from ceiling with wire connector provided.
Connect WHITE wire from fan to WHITE wire from
ceiling with wire connector provided.
Connect all GROUND (GREEN) wires together from
fan to BARE/GREEN wire from ceiling with wire
connector provided.
If you intend to control the fan light with a separate
light switch, connect BLUE wire from fan to the
BLACK (or RED) supply from the independent switch.
* Wrap each wire connector separately with electrical
tape as an extra safety measure.
7. Canopy Assembly.
Locate 2 screws on underside of hanging bracket
and remove screw closest to the open end of the
hanging bracket. Partially loosen the other screw.
Lift canopy to hanging bracket. Place rounded part
of slotted hole in canopy over loosened screw in
hanging bracket and push up. Twist canopy to lock.
Re-insert screw that was removed and then tighten
both screws securely.
white supply wire
black supply wire
from ceiling
black
white
white
black
from fan
This fan is remote control adaptable (remote
control sold separately).
screw
page 8
ground
(green or bare)
ground
(green
or bare)
*
hanging bracket
canopy
screw