General Instructions; Controller Overview; Installation; Operation Overview - BriskHeat IBC Tote Manual De Instrucciones

Calentador de tanques de 1500 vatios controlado digitalmente
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6

GENERAL INSTRUCTIONS

This electric immersion heater is designed for operation in liquid and is manufactured according to the standards and
regulations that apply when the following conditions are met:

The electric immersion heater is intended for stationary use in ordinary-area applications and hot water/liquid
heating, -or- industrial water / liquid heating in an environment where there are no hazardous-area requirements.

The entire heating element must be always immersed in water/liquid for safe operation (at least 18 inches),
otherwise the heater will be damaged or destroyed. Be sure of this before connecting power.

Because limescale on the elements may damage the electrical immersion heater, regular checks and any cleaning
must be performed.

When cleaning the outside of the terminal box, use a soft dry cloth.

CONTROLLER OVERVIEW

The microprocessor controller regulates the heating process to the desired setpoint. The unit incorporates an electronic
temperature limiter and thermal fuses as overheating protection.
See below for the control box and its layout and control buttons:
Number
Function
Description
Red LED flashes on activated alarm.
Alarm LED (red)
Green LED lit whenever heater is active.
Heat LED (green)
Decreases Setpoint, or when pressed for
about 3 seconds toggles unit ON / OFF.
‐ 
Push button
Increases setpoint, or when pressed for about 3
+
seconds
Push button
accesses menu to change the setpoint on
the hysteresis. Adjustable 2-20°F (1-10°C)
Displays current process value, setpoint, settings,
alarm as well the status of the terminal control box.

INSTALLATION

1.
Remove original Tote Tank cap and set aside.
2.
Install IBC/Tote Tank Heater into supplied threaded cap, hand tight.
3.
Install that cap into tank. Be sure that heater is immersed at least 18 inches.
4.
Plug in, turn on, adjust setpoint / hysteresis.
®
© BriskHeat
Corporation. All rights reserved
IBC/Tote Tank Immersion
Heater
.
5

OPERATION OVERVIEW

If the heater loses power or is unplugged, and then power returns, the heater will pick up where it left off. If it was ON, it
will turn ON again, and if it was OFF, it will stay OFF through a power cycle. If the heater has power, the display will
show either the current setpoint or
If the heater was OFF last, then connecting the unit to mains power causes the display to show the current software
version, and then the unit turns back OFF.
While OFF, the heater is voltage free. Press the
current process temperature. Control is now active and the heater may engage. The green LED is on to indicate heater is
ON.
The display also shows alarm information. The table below describes how these alarms are shown:
Display
Function designation
OPERATING SETPOINT
IBC/Tote Tank Immersion
.
‐ 
button for about 3 seconds and the control will switch ON and display
Alarm audio
Alarm LED
Pulsing
Flashing
Absence or Temperature Sensor Error.
Alarm automatically resets after cor-
Pulsing
Flashing
High limit temperature violation 180°F
Alarms are reset manually by power-
ing device OFF and then back ON.
Continuous
Flashing
No water in the system (No Liquid).
Alarms are reset manually by power-
ing device OFF and then back ON
Continuous
Flashing
Error on Heater (No Heating).
Alarms are reset manually by power-
ing device OFF and then back ON
Parameter
Setpoint range
41-167°F (5-75°C)
2-20°F (1-10°C)
®
© BriskHeat
Corporation. All rights reserved
6
Heater
Description
recting errors.
(82°C).
.

Publicidad

Tabla de contenido
loading

Tabla de contenido