Operation
T1. WiFi button
• WiFi configuration: if the WiFi function is not
configured, press for about 2 seconds to enter WiFi
configuration mode and follow the instructions on the App
to complete the procedure.
During the configuration procedure, the button will light
up indicating the connectivity status (see WiFi status
table)
To interrupt the WiFi configuration procedure, press for
about 2 seconds when the button is lit up and is flashing
fast.
Once the WiFi function has been configured, if you want
to change it, press for about 6 seconds to reset the WiFi
parameters (the button will turn off) and repeat the
configuration procedure.
• WiFi activation/deactivation: after the configuration, it
is possible to deactivate/activate the WiFi function. Press
for about 2 seconds to deactivate/activate the WiFi
function. Deactivating the function does not cause the
loss of the WiFi parameters.
WiFi status table
WiFi button
Light off
White light on
steady
Orange light
flashing fast
Orange light
flashing slowly
White light on with
short flashing
orange light
Device connection status
WiFi not configured or off
WiFi connected
Attempt to connect to the
WiFi router
Attempt to connect to the
Elica cloud
Remote command being
received (e.g. engine
ignition or light turned on)
T2. Suction speed (power) control button: 1, 2, 3, intensive
Note: Intensive speed lasts for about 5 minutes, then it
is automatically set to speed 3.
T3. ON/OFF button (short press) and light intensity
adjustment (long press).
Light colour temperature adjustment:
With the light ON, press and hold T1 + T3 to change the light
colour temperature.
Filter Saturation Indicator
The hood signals when necessary to perform filter
maintenance:
Grease filter (every 40 hours of use): all Leds with red light
Activated charcoal odour filter (every 160 hours of
operation): all LEDs with red light, LEDs L2 and L3 blink
Reset Filter Saturation
After performing filter maintenance, press and hold buttons T1
and T3, Leds L1, L2 and L3 blink briefly in red and then turn
off for good.
Activation indicator for odour filter saturation with
activated charcoal
This indicator is normally disabled. To enable it, proceed as
follows:
With the hood off, press and hold simultaneously T1 and T2:
L1 turns on first, then L2 and L3 and after that, when the
buttons are released, the Leds L2 and L3 flash briefly to
indicate successful activation.
Disabling the LED for charcoal filter saturation: repeat the
operation above; first the LEDs L1, L2 and L3 turn on
simultaneously, then only L1, and after that, when the buttons
are released, the leds L1, L2 and L3 turn on again to indicate
successful disabling.
18