Tools Needed For Assembly; Electrical Requirements - Emerson VERANDA CF542ORB00 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1. Unpacking Instructions
THIS FAN IS SUITABLE FOR WET LOCATIONS SUCH AS PORCHES, PATIOS, AND DECKS.
USE ONLY WITH LIGHT KITS MARKED SUITABLE FOR USE IN WET LOCATIONS.
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver
One wire stripper
Materials
Wiring outlet box and box connectors must be of type
required by the local code . The minimum wire would be
a 3-conductor (2-wire with ground) of following size:
Installed Wire Length
Up to 50 ft .
50-100 ft .
Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit .
WARNING
!
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked "Acceptable
for Fan Support of 22.7 kg. (50 lbs.) or less", and
use screws supplied with outlet box. Most outlet
boxes commonly used for support of light fixtures
are not acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt.
WARNING
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring
must be in accordance with National and Local codes
and the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
One stepladder
Wire Size A .W .G .
14
12

2. Electrical Requirements

(Continued)
!
Before assembling your ceiling fan, refer to section
on proper method of wiring your fan (page 15).
If you feel you do not have enough wiring knowledge
or experience, have your fan installed by a licensed
electrician.
The outlet box must be securely anchored and capable
of withstanding a load of at least 50 pounds .
If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time and
remove the existing light fixture .
!
To avoid fire or shock, follow all wiring instructions
carefully.
A n y e l e c t r i c a l w o r k n o t d e s c r i b e d i n t h e s e
instructions should be done or approved by a licensed
electrician.
P l e a s e c a l l E m e r s o n t e c h n i c a l s u p p o r t a t
1-800-654-3545 if you have any questions about
installation and operation of this ceiling fan .