• When battery pack is not in use, keep it away
from other metal objects, like paper clips, coins,
keys, nails, screws or other small metal objects,
that can make a connection from one terminal
to another. Shorting the battery terminals together
may cause burns or a fire.
• Under abusive conditions, liquid may be ejected
from the battery; avoid contact. If contact acciden-
tally occurs, flush with water. If liquid contacts
eyes, additionally seek medical help. Liquid
ejected from the battery may cause irritation or burns.
• Do not use a battery pack or tool that is dam-
aged or modified. Damaged or modified batteries
may exhibit unpredictable behavior resulting in fire,
explosion or risk of injury.
• Do not expose a battery pack or tool to fire or
excessive temperature. Exposure to fire or tem-
perature above 265°F (130°C) may cause explosion.
• Follow all charging instructions and do not charge
the battery pack or tool outside the temperature
range specified in the instructions. Charging im-
properly or at temperatures outside the specified range
may damage the battery and increase the risk of fire.
SERVICE
• Have your power tool serviced by a qualified
repair person using only identical replacement
parts. This will ensure that the safety of the power
tool is maintained.
• Never service damaged battery packs. Service
of battery packs should only be performed by the
manufacturer or authorized service providers.
SPECIFIC SAFETY RULES FOR
CABLE STRIPPER
To reduce the risk of explosion,
WARNING
electric shock and property dam-
age, do not use on live electrical lines. Tool is
NOT insulated. Contact with a live circuit could result
in severe injury or death. Turn off power before
stripping cable.
•To reduce the risk of personal injury, always
hold tool securely.
• Keep hands away from blade and bushing while
tool is in use. Fingers could be cut.
• To reduce the risk of injury, wear safety goggles
or glasses with side shields when operating or
servicing the tool.
•Use clamps or another practical way to secure and
support the cable to a stable platform. Holding
the cable by hand or against your body leaves
it unstable and may lead to loss of control. Be
cautious of remnants that will be eliminated from tool.
•Cable has sharp edges. Always wear gloves when
handling any type of cable.
•Inspect tool and bushing before use. A proper
connection and strip can only be achieved when
tool is clean of debris or remnants from prior use.
•The recommended bushings for the various cable
types is based off of the cable manufacturer's
published cable dimensions. Cable dimensions do
vary. If the cable does not strip properly, a smaller
or larger bushing may be needed. It is the user's
responsibility that the cable has been stripped
properly.
• Always use common sense and be cautious when
using tools. It is not possible to anticipate every
situation that could result in a dangerous outcome.
Do not use this tool if you do not understand these
operating instructions or you feel the work is beyond
your capability; contact Milwaukee Tool or a trained
professional for additional information or training.
• Maintain labels and nameplates. These carry im-
portant information. If unreadable or missing, contact
a MILWAUKEE service facility for a free replacement.
Some dust created by power sanding,
WARNING
sawing, grinding, drilling, and other
construction activities contains chemicals known to
cause cancer, birth defects or other reproductive
harm. Some examples of these chemicals are:
• lead from lead-based paint
• crystalline silica from bricks and cement and other
masonry products, and
• arsenic and chromium from chemically-treated lumber.
Your risk from these exposures varies, depending on
how often you do this type of work. To reduce your
exposure to these chemicals: work in a well ventilated
area, and work with approved safety equipment, such
as those dust masks that are specially designed to
filter out microscopic particles.
SYMBOLOGY
Volts
Direct Current
No Load Revolutions per Minute (RPM)
UL Listing for Canada and U.S.
US
C

FUNCTIONAL DESCRIPTION

2
1
1. Trigger
2. Bushing latch
3. Depth gauge lock
4. Depth gauge
5. Handle
6. Fuel gauge
7. Control switch
8. LED
SPECIFICATIONS
Cat. No. ..................................................... 2435-20
Volts.............................................................. 12 DC
Battery Type .................................................M12™
Charger Type................................................M12™
Recommended Ambient
Operating Temperature ......................0°F to 125°F
RPM ............................................................... 0 - 165
Stripping Length ..........................................1/2"- 3"
Replacement Blades .......................... 48-44-2935