Electrical Connections

Each WashBar requires the same connections.
Connect DC power adapter male barrel
B
plug into master control female barrel
plug. Plug the DC power adapter into
the blower power cord.
Air/Water Sensor
Board Connector
(Red) - From
WashBar (Shorter
of 2 Sensor
Cables - Red)
Soap Sensor
Board Connector
- From WashBar
(Longer of 2
Sensor Cables)
LED Board
Connector - From
WashBar
(Gray Cable)
Make (3) connections from
A
the WashBar assembly as
shown (Air/Water Sensor,
Soap Sensor and LED)
14

Adjust Temperature with Water Running

WARNING This valve is NOT factory preset. Upon installation, the temperature of this
valve must be checked and adjusted to ensure delivery of a safe water
temperature. Water in excess of 110°F (43°C) may cause scalding.
A
Loosen Cap Screw about ¹/₄" (4-6 turns)
and lift up cover (do not remove).
B
Using cover, turn cartridge gently until
desired water temperature is reached.
Do not turn past stops as this may
damage unit. Push cover down and
tighten screw.
Bradley • 215-1842 Rev. H: ECO 20-08-028B
This End to
Master Control
Box Female Barrel
Plug
USB for Software
Upgrades
Not Used
D
Use the cable tie hook and
loop strap to secure all
electrical cords in place.
H
To Wall
Outlet
DC Power
Adapter
Dryer
Power Cord
C
Connector Plug
to DC Valve Plug
After all connections are made,
E
reference Master Control Box:
System Startup section later in
this manual.
C
1/21/2021
LVQD1
Cable Tie
Hook and Loop
Strap
Make barrel plug and
connector plug connections
as shown.
Female Barrel
Plug to Soap
Motor Control Box
Male Barrel Plug
Connector Plug to
Dryer Motor
(Gray Cable)
21