Installation
Plaster and tile the wall, excluding the area of the structural
shell protection.
Cut off inspection chamber flush with tiles, see fold-out page II,
Fig. [1].
Flush pipes thoroughly before and after installation
(observe EN 806).
Connect fitting, see Figs. [2] to [6].
Open hot and cold water supply and check that
connections are watertight.
Temperature adjustment, see Fig. [7]
Only in conjunction with wall-mounting box 36 336.
The thermostatic cartridge is set to 38 °C at the factory.
The temperature is regulated by turning adjusting screw.
Installing the plate, see Fig. [8].
Operation
The infrared electronics emit invisible, pulsed light.
The sensor system is adjusted so that water flow is initiated
when the hands approach the vicinity of the spout. When the
hands are withdrawn from the vicinity of the spout, water flow
is stopped after 1 s.
The range of the sensor system is dependent upon the
reflective properties of the detected object.
Automatic safety shut-off
After 60 s of continuous detection of an object, the infrared
electronics automatically stop the water flow.
Maintenance
• Shut off water supply.
• Disconnect voltage supply.
• Inspect and clean all components and replace if necessary.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Water supply interrupted
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
• No voltage
- Power supply unit defective
- Power supply switched off
• Hands not in detection zone
• Cleaning mode activated
Water flowing
• Solenoid valve defective
continuously
• Thermal disinfection activated
Undesired water
• Sensor system detection zone set too high
flow
for local conditions
• Automatic flushing activated
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Filter in connection hose/thermostat dirty
• Water supply restricted
Water temperature
• Temperature incorrectly set
too high or too low
• Dirty filters or defective non-return valve
(only with 36 336)
3
I. Switched-mode power supply, see fold-out page II,
Figs. [9] and [10].
Assemble in reverse order.
II. Solenoid valve, see fold-out pages II, Figs. [9] and [11].
Assemble in reverse order.
III. Remove and clean mousseur (13 951), see fold-out
page I.
Assemble in reverse order.
IV. Wall plate with electronics, see fold-out pages II and III,
Figs. [9], [12] and [13].
Assemble in reverse order.
Thermostatic cartridge
Only in conjunction with wall-mounting box 36 336.
Disassamble plate, see fold-out page II, Fig. [9].
Disassamble thermostat, see fold-out page III, Figs. [14]
and [15].
I. Non-return valve (A) / Filters (B), see Fig. [16].
Remove union nipple (C) by turning clockwise (left-hand
thread).
Assemble in reverse order.
II. Thermostatic cartridge, see Fig. [17].
Assemble in reverse order.

Replacement parts

see fold-out page I (* = special accessories)
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
- Open shut-off valves, isolating valves
- Clean filter
- Replace solenoid valve
- Check plug-in connector
- Replace power supply unit
- Switch on voltage supply
- Hold hands directly under the spout
- Deactivate cleaning mode or wait 3 minutes
- Replace solenoid valve
- Wait 3.5 or 11 minutes
- Reduce range using remote control (special
accessory, prod. no.: 36 206)
- Wait 1 - 10 minutes
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
- Check supply lines, open shut-off valves,
isolating valves
- Adjust temperature
- Replace filters and non-return valve