Install the new the LED Array:
Secure the new LED array to the mounting bracket with the three
1.
Phillips screws.
Reconnect J1 and slide the PCB back into the housing.
2.
Tighten the captive Phillips retaining screw.
3.
Place the cover on the housing and tighten it by turning it clockwise.
4.
To ensure O-ring compression, the cover must be fully seated against
5.
the housing when the threads are tightened. Turn the M3 set screw on
the side of the housing until the screw contacts the housing.
Reconnect power to the beacon.
6.
Apply power and verify that the beacon operates properly.
7.
Lubricating the Threaded Joints
A silicone based, non-hardening, chemically compatible grease can be
applied if required.
Ordering Replacement Parts and Accessories
EXPLOSION HAZARD: A damaged lens can lead to explosions, causing
serious injury or death. If a lens is damaged, it must be replaced.
Replacement parts and accessories are listed in Table 1 below and 2 on
page 24. Due to certification, certain component parts are not available for
field replacement. Beacons with this type of damage must be either replaced
entirely or returned to Federal Signal for service.
Refer to instruction manual 25500259 for accessory and replacement part
assembly and operating instructions.
To order, call Federal Signal Customer Support at 708-534-4756 or
877-289-3246.
Model G-LED Global Series LED Beacon
Installation and Maintenance Instructions
23