EVENT
DIP 1 ON (hold-to-run mode)
Or failure of a safety device
EVENT
No transmitter code entered
DIP 1 ON > DIP 2 ON - transmitter code programming for opening
DIP 1 ON > DIP 2 ON > DIP 3 ON - transmitter code programming
for R-AUX relay
Correct transmitter codes programming for opening and R-AUX
relay
Remote control code not present in memory
Memory saturated by remote control codes (1000 codes saved)
Radio code deletion for opening, R-AUX relay
EVENT
Stop button pressed
Photocell intervention
Intervention of impact sensor
Failure of a safety device or safety device engaged for too long
Operation with emergency batteries (24 vdc)
Emergency batteries low signal
Operation with emergency batteries charged by solar panels
Failed photocells auto-test alarm
Encoder failure alarm
Functional block activated by smartphone
Achievement of set cycles
Energy saving activated by smartphone
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
BUZZER STATUS
OFF
BUZZER STATUS
OFF
OFF
OFF
1 Tone
OFF
OFF
2 Tones
WARNING SIGNALS DURING OPERATION
BUZZER STATUS
OFF
1 Tone
3 Tones
OFF
OFF
1 Tone every 5 s for 1 minute
(It is renewed by giving a command)
OFF
4 Tones every 5 s for 1 minute
(It is renewed by giving a command)
5 Tones every 5 s for 1 minute
(It is renewed by giving a command)
OFF
6 Tones every 5 s
(It is renewed by giving a command)
OFF
35
FLASHER STATUS
OFF
Flashes ON/OFF 250 ms
FLASHER STATUS
OFF
Flashes red/green
OFF
Flashes red for 10 s
OFF
Flashes orange for 10 s
OFF
Turns green once
OFF
Red flash
OFF
Runs 6 green flashes
OFF
Runs 2 green flashes
FLASHER STATUS
LED STATUS AND SIGNAL OUTPUT
OFF
Led DL6 turns OFF
OFF
Led DL7-8 turns OFF
OFF
No led combined
OFF
Led DL1 flashes ON/OFF 250 ms
Signal output flashes ON/OFF twice for 250 ms
Flashes on movement
followed by a pause of 2 seconds
Signal output flashes continuously ON/OFF for 500
OFF
ms
Signal output flashes ON/OFF 3 times for 250 ms
OFF
followed by a pause of 2 seconds
OFF
No led combined
Flashes for 1 minute Led DL2 OFF
OFF
Led DL12 is steady on green.
OFF
No leds matched
OFF
Blue led flashes once every 5 s
G
B
DL1 LED STATUS
DL10 LED STATUS